MB39C015
16. Evaluation Board Specification
The MB39C015 Evaluation Board provides the proper for evaluating the efficiency and other characteristics of the MB39C015.
■ Terminal information
Symbol
VIN
VOUT1, VOUT2
VCTL
CTL1, CTL2
MODE1, MODE2
VREF
VREFIN1, VREFIN2
VDET
CTLP
XPOR
VXPOR
PGND
AGND
Functions
Power supply terminal
In standard condition 3.1 V to 5.5 V*
* : When the VIN/VOUT difference is to be held within 0.6 V or less, such as for devices with a
standard output voltage (VOUT1  2.5 V) when VIN < 3.1 V, Cypress recommends changing
the output capacity (C1, C2) to 10 F.
Output terminals
(VOUT1: CH1, VOUT2: CH2)
Power supply terminal for setting the CTL1, CTL2 and CTLP terminals.
Use by connecting with CTL1,CTL2 and CTLP.
Direct supply terminal of CTL (CTL1 : for CH1, CTL2 : for CH2)
CTL1, CTL2  0 V to 0.8 V (Typ.) : Shutdown
CTL1, CTL2  0.95 V (Typ.) to VIN (5 V Max) : Normal operation
TEST terminal
MODE1, MODE2  OPEN or GND
Reference voltage output terminal
VREF  1.30 V (Typ.)
External reference voltage input terminals
(VREFIN1 : for CH1, VREFIN2 : for CH2)
When an external reference voltage is supplied, connect it to the terminal for each channel.
Voltage input terminal for voltage detection
Voltage detection circuit block control terminal
CTLP  L : Voltage detection circuit block stop
CTLP  H : Normal operation
Voltage detection circuit output terminal
The N-ch MOS open drain circuit is connected.
Pull-up voltage terminal for the XPOR terminal
Ground terminal
Connect power supply GND to the PGND terminal next to the VIN terminal.
Connect output (load) GND to the PGND terminal between the VOUT1 terminal and the VOUT2 terminal.
Ground terminal
■ Startup terminal information
Terminal name
Condition
CTL1
L : Open
H : Connect to VCTL
CTL2
L : Open
H : Connect to VCTL
CTLP
L : Open
H : Connect to VCTL
Functions
ON/OFF switch for CH1
L : Shutdown
H : Normal operation.
ON/OFF switch for CH2
L : Shutdown
H : Normal operation.
ON/OFF switch for the voltage detection block
L: Stops the voltage detection circuit
H: Normal operation.
Document Number: 002-08364 Rev. *A
Page 34 of 43