English
Language : 

FX919A Datasheet, PDF (28/44 Pages) CML Microcircuits – 4-Level FSK Modem Data Pump
4-Level FSK Modem Data Pump
FX919A
1.5.6 CRC, FEC and Interleaving
Cyclic Redundancy Codes
CRC1
This is a sixteen-bit CRC check code contained in bytes 10 and 11 of the Header Block. It is calculated by the
modem from the first 80 bits of the block ( Bytes 0 to 9 inclusive) using the generator polynomial:
x16 + x12 + x5 + 1
CRC2
This is a thirty-two-bit CRC check code contained in bytes 8 to 11 of the 'Last' Block. It is calculated by the
modem from all of the data and pad bytes in the Intermediate Blocks and in the first 8 bytes of the Last Block
using the generator polynomial:
x32 + x26 + x23 + x22 + x16 + x12 + x11 + x10 + x8 + x7 + x5 + x4 + x2 + x1 + 1
Note: In receive mode the CRC2 checksum circuits are initialised on completion of any task other than NULL or
RILB. In transmit mode the CRC2 checksum circuits are initialised on completion of any task other than NULL,
TIB or TLB.
Forward Error Correction
In transmit mode, the FX919A uses a Trellis Encoder to translate the 96 bits (12 bytes) of a 'Header',
'Intermediate' or 'Last' Block into a 66-symbol sequence which includes FEC information.
In receive mode, the FX919A decodes the received 66 symbols of a block into 96 bits of binary data using a
'Soft Decision' Viterbi algorithm to perform decoding and error correction.
Interleaving
The 66 symbols of a 'Header', 'Intermediate' or 'Last' block are interleaved by the modem before transmission
to give protection against the effects of noise bursts and short fades.
In receive mode, the FX919A de-interleaves the received symbols prior to decoding.
© 1996 Consumer Microcircuits Limited
28
D/919A/4