English
Language : 

CS42516 Datasheet, PDF (14/91 Pages) Cirrus Logic – 110 dB, 192 kHz 6-Ch Codec with S/PDIF Receiver
CS42516
SWITCHING CHARACTERISTICS - CONTROL PORT - SPI™ FORMAT
(For CQZ, TA = -10 to +70° C; For DQZ, TA = -40 to +85° C; VA=VARX = 5 V, VD =VLS= 3.3 V; VLC = 1.8 V to
5.25 V; Inputs: Logic 0 = DGND, Logic 1 = VLC, CL = 30 pF)
Parameter
CCLK Clock Frequency
CS High Time Between Transmissions
CS Falling to CCLK Edge
CCLK Low Time
CCLK High Time
CDIN to CCLK Rising Setup Time
CCLK Rising to DATA Hold Time
CCLK Falling to CDOUT Stable
Rise Time of CDOUT
Fall Time of CDOUT
Rise Time of CCLK and CDIN
Fall Time of CCLK and CDIN
Symbol Min Typ Max Units
(Note 20)
fsck
tcsh
tcss
tscl
tsch
tdsu
(Note 21)
tdh
tpd
tr1
tf1
(Note 22)
tr2
(Note 22)
tf2
0
-
6.0
MHz
1.0
-
-
µs
20
-
-
ns
66
-
-
ns
66
-
-
ns
40
-
-
ns
15
-
-
ns
-
-
50
ns
-
-
25
ns
-
-
25
ns
-
-
100
ns
-
-
100
ns
Notes:
20. If Fs is lower than 46.875 kHz, the maximum CCLK frequency should be less than 128 Fs. This is
dictated by the timing requirements necessary to access the Channel Status and User Bit buffer
memory. Access to the control register file can be carried out at the full 6 MHz rate. The minimum
allowable input sample rate is 8 kHz, so choosing CCLK to be less than or equal to 1.024 MHz should
be safe for all possible conditions.
21. Data must be held for sufficient time to bridge the transition time of CCLK.
22. For fsck <1 MHz.
CS
t css
t scl t sch
t csh
CCLK
t r2
t f2
CDIN
CDOUT
t dsu
t dh
t pd
Figure 4. Control Port Timing - SPI Format
14