English
Language : 

CM1231 Datasheet, PDF (7/11 Pages) California Micro Devices Corp – Two-Channel PicoGuard XPTM ESD Clamp Protection Array
Issue X-1
CM1231
ELECTRICAL OPERATING CHARACTERISTICS (SEE NOTE 1)
SYMBOL PARAMETER
VP
Operating Supply Voltage
ICC5 Operating Supply Current
VF
Diode Forward Voltage
Top Diode
Bottom Diode
VESD
ESD Protection, Contact Discharge per
IEC 61000-4-2 Standard
OUT-to-VN Contact
IN-to-VN Contact
IRES Residual ESD Peak Current on RDUP
(Resistance of Device Under Protection)
VCL
RDYN
COUT
Channel Clamp Voltage
Positive Transients
Negative Transients
Dynamic Resistance
Positive Transients
Negative Transients
OUT Capacitance
ΔCOUT Channel to Channel Capacitance Match
RS
ΔRS
Series Resistance
Channel to Channel Resistance Match
CONDITIONS
MIN
VP = 5V
IF = 8mA, TA = 25°C;
Note 2
TA = 25°C;
Note 2
0.60
0.60
±12
±4
IEC 61000-4-2 8kV;
RDUP = 5Ω, TA = 25°C;
Note 2
IPP = 1A, TA = 25°C, tP = 8/20µs,
Zap at OUT, Measure at IN;
Note 2
IPP = 1A, TA = 25°C, tP = 8/20µs,
Zap at OUT, Measure at IN;
Note 2
f=1 MHz, VP=5.0V, VIN=2.5V,
VOSC=30mV;
Note 2, 3
f=1 MHz, VP=5.0V, VIN=2.5V,
VOSC=30mV
Note 2
Note 2
Note 2
TYP
5
0.80
0.80
2.3
+9
–1.4
0.4
0.3
1.5
0.02
1
±10
Note 1: All parameters specified at TA = –40°C to +85°C unless otherwise noted.
Note 2: This parameter is guaranteed by design and verified by device characterization
Note 3: Capacitance measured from OUT to VN with IN floating.
MAX UNITS
5.5
V
1
μA
0.95
V
0.95
V
kV
kV
A
V
V
Ω
Ω
pF
pF
Ω
±30 mΩ
© 2007 California Micro Devices Corp. All rights reserved.
12/17/07
490 N. McCarthy Blvd., Milpitas, CA 95035-5112 ● Tel: 408.263.3214 ● Fax: 408.263.7846 ● www.cmd.com 7