English
Language : 

HBCU-5710R Datasheet, PDF (8/25 Pages) AVAGO TECHNOLOGIES LIMITED – Designed for Industry-Standard MSA-Compliant, Small Form Factor Pluggable (SFP) Ports
Transmitter and Receiver Electrical Characteristics
(TC = 0 °C to +70 °C, VCCT, R = 3.3 V ± 5%)
Parameter
Symbol
Data Input:
VI
Transmitter Differential Input Voltage (TD +/-)
Data Output:
VO
Receiver Differential Output Voltage (RD +/-)
Receive Data Rise & Fall Times (Receiver)
Trf
Minimum Typical
500
600
Maximum Unit
2400
mV
800
mV
250
ps
Notes
Note 1
Note 2
Note 3
Note 4
Transceiver Timing Characteristics
(TC = 0 °C to +70 °C, VCCT, R = 3.3 V ± 5%)
Parameter
Symbol
Tx Disable Assert Time
t_off
Tx Disable Negate Time
t_on
Module Reset Assert Time
t_off_rst
Module Reset Negate Time
t_on_rst
Time to initialize
t_init
Tx Fault Assert Time
t_fault
Tx Disable to Reset
t_reset
Rate Select Change Time
t_ratesel
Serial ID Clock Rate
F_serial_clock
Minimum Typical
Maximum Unit
NA
NA
10
µs
300
µs
300
ms
NA
NA
NA
100
kHz
Notes
Note 5
Note 5
Note 6
Note 7
Notes:
1. Internally ac coupled and terminated (100 Ohm differential). These levels are compatible with CML and LVPECL voltage swings.
2. Internally ac coupled with an external 100 ohm differential load termination.
3. Represents nominal output voltage. User may change values through register 26.2:0. Please refer to Table 19 for output settings.
4. 20%-80% rise and fall times measured from the module’s internally generated Gigabit Ethernet idle pattern at 1.25 Gbps.
5. Tx Disable function as described in the SFP MSA is not used in the 1000BASE-T module.
6. Time from rising edge of Tx Disable until link comes down.
7. Time from falling edge of Tx Disable until auto-negotiation starts.