Absolute Maximum Ratings
Parameter
Storage Temperature
Case Temperature
Relative Humidity
Module Supply Voltage
Data/Control Input Voltage
Sense Output Current - MOD-DEF 2
Symbol
TS
TC
RH
VCCT,R
VI
Minimum
-40
-40
5
-0.5
-0.5
Typical
Maximum Unit
+75
°C
+75
°C
95
%
3.6
V
VCC
V
5.0
mA
Notes
Note 1
Note 1, 2
Note 1
Note 1, 2
Note 1
Recommended Operating Conditions
Parameter
Symbol
Minimum Typical
Maximum Unit
Notes
Case Temperature
Module Supply Voltage
Data Rate
TC
0
VCCT,R
3.135
3.3
1.25
+70
°C
3.465
V
Gb/s
Note 3
Note 3
Note 3
Transceiver Electrical Characteristics
(TC = 0 °C to +70 °C, VCCT, R = 3.3 V ± 5%)
Parameter
Symbol
Minimum Typical
Maximum Unit Notes
Bit Error Rate
BER
10-10
Note 4
AC Electrical Characteristics
Power Supply Noise Rejection (peak-peak)
PSNR
100
mV
Note 5
DC Electrical Characteristics
Module supply current
ICC
370
mA
Note 6
Power Dissipation
PDISS
1150
mW
Sense Outputs:
MOD-DEF 2
VOH
2.4
VOL
VCCT,R+0.3 V
0.4
V
Note 7
Control Inputs:
Transmitter Disable
MOD-DEF 1,2
VIH
2.0
VIL
0
VCC
V
Note 7
0.8
V
Control Inputs:
Transmitter Disable
(TX_DISABLE)
VIH
2.0
VIL
0
VCC
V
0.4
V
Notes:
1. Absolute Maximum Ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short
period of time. See Reliability Data Sheet for specific reliability performance.
2. Between Absolute Maximum Ratings and the Recommended Operating Conditions functional performance is not intended, device reliability
is not implied, and damage to the device may occur over an extended period of time.
3. Recommended Operating Conditions are those values outside of which functional performance is not intended, device reliability is not implied,
and damage to the device may occur over an extended period of time. See Reliability Data Sheet for specific reliability performance later when
it is ready.
4. 100 m Cat 5 cable.
5. MSA-specified filter is required on the host board to achieve PSNR performance over the frequency range 10 Hz to 2 MHz.
6. ICC max at 3.1 V, +70 °C.
7. LVTTL, external 4.7-10 KW pull-Up resistor required.