English
Language : 

HCPL-3180-500E Datasheet, PDF (7/16 Pages) AVAGO TECHNOLOGIES LIMITED – 2.5 Amp Output Current, High Speed, Gate Drive Optocoupler
Switching Specifications (AC)
Over recommended operating conditions unless otherwise specified.
Test
Parameter
Symbol Min.
Typ.
Max. Units Conditions
Fig.
Note
Propagation Delay Time to tPLH
50
150 200 ns
High Output Level
Propagation Delay Time to tPHL
50
150 200 ns
Low Output Level
IF = 10 mA,
Rg = 10 Ω,
f = 250 kHz,
10, 11, 14
12, 13,
14, 23
Pulse Width Distortion
PWD
20
65
ns
Duty Cycle = 50%,
10
Propagation Delay
PDD
-90
90
ns
Cg = 10 nF
34, 35 10
Difference Between Any
(tPHL-tPLH)
Two Parts or Channels
Rise Time
tr
25
ns
CL = 1 nF,
23
Fall Time
tf
25
ns
Rg = 0 Ω
UVLO turn On Delay
tUVLO ON
2.0
µs
22
UVLO turn Off Delay
tUVLO OFF
0.3
µs
22
Output High Level Common |CMH| 10
kV/µs TA = 25°C,
24
Mode Transient Immunity
IF = 10 to 16 mA,
11, 12
Output Low Level Common |CML|
10
kV/µs VCM = 1.5 kV,
24
Mode Transient Immunity
VCC = 20 V
11, 13
Package Characteristics
Test
Parameter
Symbol Min.
Typ.
Max. Units Conditions
Fig.
Note
Input-Output Momentary
VISO
3750
Vrms
TA = 25°C,
8,9
Withstand Voltage
RH < 50%
Input-Output Resistance
RI-O
10[11]
Ω
VI-O = 500 V
9
Input-Output Capacitance
CI-O
1
pF
Freq = 1 MHz
Notes:
1. Derate linearly above +70°C free air temperature at a rate of 0.3 mA/°C.
2. Maximum pulse width = 10 µs, maximum duty cycle = 0.2%. This value is intended to allow for component tolerances for designs with IO peak
minimum = 2.0 A. See Application section for additional details on limiting IOL peak.
3. Derate linearly above +70°C, free air temperature at the rate of 4.8 mW/°C.
4. Derate linearly above +70°C, free air temperature at the rate of 5.4 mW/°C. The maximum LED junction temperature should not exceed
+125°C.
5. Maximum pulse width = 50 µs, maximum duty cycle = 0.5%.
6. In this test, VOH is measured with a dc load current. When driving capacitive load VOH will approach VCC as IOH approaches zero amps.
7. Maximum pulse width = 1 ms, maximum duty cycle = 20%.
8. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage > 4500 Vrms for 1 second (leakage detec-
tion current limit II-O < 5 µA).
9. Device considered a two-terminal device: pins on input side shorted together and pins on output side shorted together.
10. PWD is defined as |tPHL - tPLH| for any given device.
11. Pin 1 and 4 need to be connected to LED common.
12. Common mode transient immunity in the high state is the maximum tolerable dVCM/dt of the common mode pulse VCM to assure that the
output will remain in the high state (i.e. VO > 10.0 V).
13. Common mode transient immunity in a low state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the out-
put will remain in a low state (i.e. VO < 1.0 V).
14. tPHL propagation delay is measured from the 50% level on the falling edge of the input pulse to the 50% level of the falling edge of the VO
signal. tPLH propagation delay is measured from the 50% level on the rising edge of the input pulse to the 50% level of the rising edge of the
VO signal.
15. The difference between tPHL and tPLH between any two HCPL-3180 parts under same test conditions.
7