Operating Characteristics
Table 1. Absolute Maximum Ratings
(All voltages below are referenced to VSS)
Parameter
DC Supply Voltage
Input Voltage
Storage Temperature
Operating Temperature [1]
Symbol
VDD
VIN
TS
TA
Limits
-0.3 to +6.0
-0.3 to (VDD +0.3)
-55 to +150
-40 to +85
Units
V
V
°C
°C
Table 2. Recommended Operating Conditions
Parameter
DC Supply Voltage
Ambient Temperature [1]
Symbol
VDD
TA
Limits
4.5 to 5.5
-40 to +85
Units
V
°C
Table 3. DC Characteristics VDD = 5V ± 5%; TA = -40 to 85°C
Symbol Parameter
Condition
Min
Typ
Max Unit
V [2]
IL
Low-Level Input Voltage
1.5
V
V [2]
IH
High-Level Input Voltage
3.5
V
VT+
Schmitt-Trigger Positive-Going Threshold
3.5
4.0
V
VT-
Schmitt-Trigger Negative-Going Threshold
1.0
1.5
V
VH
Schmitt-Trigger Hysteresis
1.0
2.0
V
IIN
Input Current
VIN=VSS or VDD
-10
1
+10
A
V [2]
OH
High-Level Output Voltage
IOH = -3.75 mA
2.4
4.5
V
V [2]
OL
Low-Level Output Voltage
IOL = +3.75mA
0.2
0.4
V
IOZ
High-Z Output Leakage Current
VO=VSS or VDD
-10
1
+10
A
IDD
Quiescent Supply Current
VIN=Vss or VDD
1
100
A
C [3]
IN
Input Capacitance
Any Input
5
pF
C [3]
OUT
Output Capacitance
Any Output
5
pF
Notes:
1. Free Air
2. In general, for any VDD between the allowable limits (+4.5V to +5.5V), VIL = 0.3VDD and VIH = 0.7VDD; typical values are VOH = VDD –
0.5V and VOL = VSS + 0.2V
3. Including package capacitance but excluding PCB capacitance.