39.7.27 PWM Fault Protection Enable Register
Name:
Address:
PWM_FPE
0x4002006C
Access: Read/Write
31
30
29
28
27
26
25
24
FPE3
23
22
21
20
19
18
17
16
FPE2
15
14
13
12
11
10
9
8
FPE1
7
6
5
4
3
2
1
0
FPE0
This register can only be written if bits WPSWS5 and WPHWS5 are cleared in the “PWM Write Protection Status Register”
.
Only the first 8 bits (number of fault input pins) of fields FPE0, FPE1, FPE2 and FPE3 are significant.
• FPEx: Fault Protection Enable for channel x
For each field bit y (fault input number):
0: Fault y is not used for the Fault Protection of channel x.
1: Fault y is used for the Fault Protection of channel x.
CAUTION: To prevent an unexpected activation of the Fault Protection, the bit y of FPEx field can be set to ‘1’ only if the
corresponding FPOL field has been previously configured to its final value in “PWM Fault Mode Register” .