7. Electrical Characteristics (Continued)
VS = 3.6V with AUX regulator, Tamb = 25°C, unless otherwise specified
No. Parameters
Test Conditions
Symbol
Min.
Typ. Max. Unit
8 Synthesizer
8.1
External reference input
frequency
D7 = 0
D7 = 1
REF_CLK
10.368
13.824
MHz
MHz
8.2
Sinusoidal input signal level
(peak-to-peak value)
AC-coupled sine wave
REF_CLK
500
1000 mVPP
8.3 Scaling factor prescaler
8.4 Scaling factor main counter
8.5 Scaling factor swallow counter
9 Phase Detector
SPSC
SMC
SSC
32/33
-
86/87/88/89
-
0
31
-
9.1
Phase detector comparison
frequency
fPD
1728
kHz
10 Charge-pump Output
10.1 Charge-pump output current
10.2 Leakage current
11 Timing Conditions(1)(2)
VCP = 1/2 VCC
VCP = 1/2 VCC
ICP
±2
mA
IL
±100 1000
pA
11.1 Transmit to receive time
Reference clock stable
TX → RX time
200
µs
11.2 Receive to transmit time
Reference clock stable
RX → TX time
200
µs
11.3 Channel switch time
Reference clock stable
CS time
200
µs
11.4 Power down to transmit
Reference clock stable
PD → TR time
250
µs
11.5 Power down to receive
Reference clock stable
PD → RX time
200
µs
11.6 Programming register
Reference clock stable
PRR time
3
µs
11.7 PLL settling time
Reference clock stable
PLL set time
200
µs
12 Interface Logic Input and Output Signal Levels, Pin DATA, CLOCK, ENABLE
12.1 HIGH-level input voltage
Logic 1
VIH
1.4
3.1
V
12.2 LOW-level input voltage
Logic 0
VIL
–0.3
+0.4
V
12.3 HIGH-level output voltage
Logic 1
VOH
3.1
V
12.4 LOW-level output voltage
Logic 0
VOL
0
V
12.5 Input bias current
Logic 1 or logic 0
Ibias
–5
+5
µA
12.6 3-wire bus clock frequency
fCLKmax
10
MHz
Notes: 1. Measured and guaranteed only on the Atmel® evaluation board, including microstrip filter, balun, and smart radio fre-
quency (smart RF) firmware. Conducted measured.
2. Timing is determined by external loop filter characteristics. Faster timing can be achieved by modification of the loop fil-
ter. For further information refer to the application notes.
3. The Gaussian filter control setting (GFCS) is used to compensate production tolerances by tuning the modulation devia-
tion in production to the nominal value of 400kHz.
4. Burst mode with 0.9% duty cycle
ATR2406 [DATASHEET]
9
4779Q–ISM–09/14