7. Electrical Characteristics
VS = 3.6V with AUX regulator, Tamb = 25°C, unless otherwise specified
No. Parameters
Test Conditions
Symbol
Min.
Typ. Max. Unit
1 Supply
1.1 Supply voltage
With AUX regulator
VS
1.2 Supply voltage
Without AUX regulator
VS
1.3 RX supply current
CW mode (peak current)
Burst mode at 10Kbits/s(4)
IS
IS
1.4 TX supply current
CW mode (peak current)
Burst mode at 10Kbits/s(4)
IS
IS
Battery lifetime of a remote
See Section 11. “Appendix:
1.5 control application using an
AVR®
Current Calculations for a Remote
Control” on page 21
3.2
3.6
4.6
V
2.9
3.0
3.6
V
57
mA
625
µA
42
mA
500
µA
1.6
Supply current in power-down
mode
With AUX regulator
PU_TRX = 0; PU_REG = 0
IS
<1
µA
1.7
Supply current in power-down
mode
Without AUX regulator
PU_TRX = 0; PU_REG = 0
IS
<1
µA
2 Voltage Regulator
2.1 AUX regulator
VREG
3.0
V
2.2 VCO regulator
VREG_VCO
2.7
V
3 Transmitter Part
3.1 TX data rate
72/144/288/576/1152
kBits/s
3.2 Output power
PTX
4
dBm
3.3 TX data filter clock
9 taps in filter
3.4 Frequency deviation
To be tuned by GFCS bits
3.5
Frequency deviation scaling(3)
GFFM = GFFM_nom × GFCS
(Refer to bus protocol D9 to D11)
fTXFCLK
GFFM_nom
GFCS
10.368/13.824
±400
60
130
MHz
kHz
%
3.6 Frequency drift
3.7 Harmonics
With standard loop filter and slot
length of 1400µs (refer to the
application note “ATR2406 Loop
Filter and Data Rates”)
BW = 100kHz(1)
Dfo (drift)
±40
kHz
–41.2 dBm
Spurious emissions
30 to 1000MHz
3.8 1 to 12.75GHz
1.8 to 1.9GHz
5.15 to 5.3GHz
BW = 100kHz(1)
–57 dBm
–57 dBm
–57 dBm
–57 dBm
4 Ramp Generator, Pin 21
4.1 Minimum output voltage
TX_ON = low
Vmin
0.7
V
4.2 Maximum output voltage
Refer to bus protocol D12 to D13
Vmax
1.1
1.9
V
4.3 Rise time
tr
5
µs
Notes: 1. Measured and guaranteed only on the Atmel® evaluation board, including microstrip filter, balun, and smart radio fre-
quency (smart RF) firmware. Conducted measured.
2. Timing is determined by external loop filter characteristics. Faster timing can be achieved by modification of the loop fil-
ter. For further information refer to the application notes.
3. The Gaussian filter control setting (GFCS) is used to compensate production tolerances by tuning the modulation devia-
tion in production to the nominal value of 400kHz.
4. Burst mode with 0.9% duty cycle