■ Digital High Pass Filter
The ADC has a digital high pass filter for DC offset cancellation. The cut-off frequency of the HPF is 1.0Hz
(@fs=48kHz) and scales with sampling rate (fs).
■ Power-down
The AK5367 is placed in the power-down mode by bringing PDN pin = “L” and the digital filter is also reset at the same
time. This reset should always be done after power-up. At the power-down mode, the VCOM voltage is become VSS1.
After exiting the power-down mode, the Charge pump circuit is powered up, and then Pre-Amp circuit is auto powered up
and an analog initialization cycle starts(Figure 10). Therefore, the output data SDTO becomes available after 4388 x
LRCK cycles at slave mode, and 4385 x LRCK cycles at master mode. In the initialization, the both channel of ADC
output is “0” of 2’s complement. After the initialization, the ADC output is settled to the data equal to analog input
signal.(the setting time is same as group delay)
Power Supply
(1)
(AVDD, DVDD, CVDD)
PDN
Charge Pump
Internal State
CVEE Pin
Power-down power-up
(5)
0V
-CVDD
ADC
Internal State
Power-down power-up Initialize
Pre-amp In
(Analog)
(3)
ADC OUT
(Digital)
Clock In
MCLK,LRCK,BICK
“0”data
(1)
Normal Operation
Power-down power-up
(5)
0V
Normal Operation
-CVDD
Normal Operation
(2)
(2)
GD
GD
Power-down power-up Initialize
Normal Operation
(2)
GD
Idle Noise
Idle Noise
(3)
“0”data
(4)
Idle Noise
Notes:
(1) 4388/fs at slave mode, 4385/fs at master mode.
(2) Analog output corresponding to digital input has group delay (GD).
(3) ADC output is “0” data at the power-down mode.
(4) Place the AK5367 in power-down mode if MCLK, BICK and LRCK are not present.
(5) Power-up time of Charge Pump Circuit. 260/fs (slave mode), 257/fs (master mode).
Figure 10. Power-down/up sequence example