English
Language : 

705-5100-111 Datasheet, PDF (6/28 Pages) Magnetrol International, Inc. – Eclipse® Enhanced Model 705 Guided Wave Radar Level Transmitter
TRANSMITTER SPECIFICATIONS
FUNCTIONAL/PHYSICAL
Power (at terminals) General Purpose / Intrinsically Safe
11 to 28.6 VDC
Explosion Proof (with Intrinsically Safe probe)
11 to 36 VDC
FOUNDATION fieldbus™ and PROFIBUS PA™ (FISCO)
9 to 17.5 VDC
FOUNDATION fieldbus™ and PROFIBUS PA™ (FNICO Exd)
9 to 32 VDC
Signal Output
4–20 mA with HART®
3.8 mA to 20.5 mA useable (meets NAMUR NE 43)
FOUNDATION fieldbus™
H1 (ITK Ver. 5.01) or Profibus PA™ H1
PROFIBUS PA™
Span
6" to 75' (15 mm to 22 m) except 7xS: max 15' (45 m)
Resolution
Analog: 0.01 mA
Display: 0.1 (inches or centimeters)
Loop Resistance
630 Ω @ 20.5 mA - 24 VDC
Damping
Adjustable 0-10 s
Diagnostic Alarm
Adjustable 3.6 mA, 22 mA, HOLD
User Interface
HART® communicator, AMS® or PACTware®, FOUNDATION fieldbus™, PROFIBUS PA™,
and/or 3-button keypad
Display
2-line x 8-character LCD
Menu Language
English/Spanish/French/German (FOUNDATION fieldbus™ and PROFIBUS PA: English)
Housing Material
SIL Œ
(Safety Integrity
Level)
Standard
electronics
Enhanced
electronics
IP 66/Aluminium A356T6 (< 0.20 % copper) 316 stainless steel
Functional safety to SIL 1 as 1oo1 / SIL 2 as 1oo2 in accordance to 61508 – SFF of 85.4 %
– full FMEDA reports and declaration sheets available at request
Functional safety to SIL 2 as 1oo1 in accordance to 61508 – SFF of 91 %
– full FMEDA reports and declaration sheets available at request
Electrical Data
Ui = 28.4 V, li = 94 mA, Pi = 0.67 W
Ci = 0.56 V, li = 380 mA, Pi = 5.32 W (FOUNDATION fieldbus™ / PROFIBUS PA)
Equivalent Data
Ci = 2.2 nF, Li = 3 µH
Ci = 0.56 nF, Li = 3 µH (FOUNDATION fieldbus™ / PROFIBUS PA)
Shock/Vibration Class
ANSI/ISA-571.03 SA1 (Shock), ANSI/ISA-571.03 VC2 (Vibration)
Net and Gross
Weight
Cast aluminium
Stainless steel
6 lbs. (2.7 kg) net; 7 lbs. (3.2 kg) gross – transmitter only
12.5 lbs. (5.7 kg) net; 13.5 lbs. (6.2 kg) gross – transmitter only
Overall Dimensions
H 8.43" (214 mm) x W 4.38" (111 mm) x D 7.40" (188 mm)
FOUNDATION fieldbus™ ITK Version
specifications
H1 Device Class
5.01
Link Master (LAS) – selectable ON/OFF
H1 Profile Class
31PS, 32L
Function Blocks
1 x RB (s), 4 x AI (s), 1 x TB (c), and (1) PID
Quiescent current draw 15 mA
Execution time
15 ms (45 msec PID Block)
CFF files
Downloads available from Host system supplier or www.fieldbus.org
Profibus PA
specifications
Device revision
Digital communication
protocol
0x01
Version 3.0 MBP (31.25 kbits/sec)
Function Blocks
1 × PB, 4 × Al blocks, 1 × TB
Quiescent current draw
15 mA
Execution time
15 ms
GSD files
Downloads available from www.profibus.com or Magnetrol.com
Œ Not applicable for FOUNDATION fieldbus™ and PROFIBUS PA™ units.
6