English
Language : 

705-5100-111 Datasheet, PDF (26/28 Pages) Magnetrol International, Inc. – Eclipse® Enhanced Model 705 Guided Wave Radar Level Transmitter
MODEL NUMBER
PFA INSULATED/ FACED-FLANGE PROBE FOR
A G G R E S S I V E L I Q U I D S (FOR IN-TANK MOUNTING ONLY)
BASIC MODEL NUMBER
7 * F-F Single rod PFA insulated 316/316L (1.4401/1.4404) GWR probe
*Specify “E” for English (e.g., 7EF-F) or “M” for Metric (e.g., 7MF-F)
εr ≥ 1.9/10 Œ
PROCESS CONNECTION – SIZE/TYPE
ANSI Flanges
4 3 2" 150# ANSI RF flange
EN/DIN Flanges
D A DN 50, PN 16 EN 1092-1 Type A
4 4 2" 300# ANSI RF flange
4 5 2" 600# ANSI RF flange
5 3 3" 150# ANSI RF flange
D B DN 50, PN 25/40 EN 1092-1 Type A
D D DN 50, PN 63 EN 1092-1 Type B2
D E DN 50, PN 100 EN 1092-1 Type B2
5 4 3" 300# ANSI RF flange
5 5 3" 600# ANSI RF flange
6 3 4" 150# ANSI RF flange
E A DN 80, PN 16 EN 1092-1 Type A
E B DN 80, PN 25/40 EN 1092-1 Type A
E D DN 80, PN 63 EN 1092-1 Type B2
6 4 4" 300# ANSI RF flange
6 5 4" 600# ANSI RF flange
E E DN 80, PN 100 EN 1092-1 Type B2
F A DN 100, PN 16 EN 1092-1 Type A
F B DN 100, PN 25/40 EN 1092-1 Type A
F D DN 100, PN 63 EN 1092-1 Type B2
F E DN 100, PN 100 EN 1092-1 Type B2
7
F
F
INSERTION LENGTH
24 to 240 inches (60 to 610 cm)
(unit of measure is determined by second digit of Model Number)
Examples: 24 inches = 024; 60 centimeters = 060
Œ For dielectric range ≤1.9 and 10, probe must be mounted
within 2–6 inches (50–150 mm) distance from the tank wall or
in a cage or bridle. See mounting consideration on page 25.
N
FLEXIBLE CABLE PROBES FOR LIQUIDS OR SOLIDS
BASIC MODEL NUMBER – GWR probe suited for external cage and/or in-tank mounting
7 * 1-A Single cable GWR probe in 316 stainless steel
For liquid level
7 * 7-A Twin cable GWR probe in FEP coated 316 stainless steel For liquid level
7 * 2-A Single cable GWR probe in 316 stainless steel
7 * 5-A Twin cable GWR probe in 316 stainless steel
For solids level (use only Viton® process seal)
For solids level (use only Viton® process seal)
*Specify “E” for English (e.g., 7EF-F) or “M” for Metric (e.g., 7MF-F)
PROCESS CONNECTION – SIZE/TYPE
Threaded
4 1 2" NPT thread
4 2 2" BSP (G2) thread
ANSI Flanges & EN/DIN Flanges
Refer to charts in above section.
(ANSI codes 43, 44, 45 & EN DIN codes DA, DB, DD, DE
not available with 7*7/7*5 GWR probes)
PROCESS SEAL – O-RING MATERIAL
0 Viton® GFLT seal: for universal use
-40° F (-40° C) / +400° F (+200° C)
INSERTION LENGTH – Specify per 1' (1 m) increments
0 0 3 min 3' (1 m) for model 7*1
0 0 6 min 6' (2 m) for models 7*2, 7*7, 7*5
0 4 0 max 40' (12 m) for model 7*7 for liquid interface
0 7 5 max 75' (22 m) all models except 7*7 for liquid interface
7
A
0
26