English
Language : 

705-5100-111 Datasheet, PDF (5/28 Pages) Magnetrol International, Inc. – Eclipse® Enhanced Model 705 Guided Wave Radar Level Transmitter
SELECTION GUIDE
COAXIAL TYPE GWR PROBE
TWIN ROD/CABLE TYPE GWR PROBE
SINGLE ROD/CABLE TYPE
signal propagation
signal propagation
signal propagation
end view
end view
Application
Dielectric
Limit
Temperature
Limits
Pressure
Applications
Vacuum ΠOverfill Safe
Foam 
GWR
Probe
Coaxial GWR Probes: Maximum Viscosity 500 cP (I.D. 3⁄4") – 1500 cP (I.D. 13⁄4")
Level
εr 1.4–100
-40° to +400° F max 1015 psig
(-40° to +200° C) (70 bar)
Yes
Yes
No
ε High Temp./High Pressure
Level/Interface
r 1.4–100 Ž
-321° to 800° F max 6250 psig
(-196° to +430° C) (430 bar)
Full
Yes
No
Saturated Steam
εr 10–100
up to +650° F max 2250 psig
(up to +345° C) (155 bar)
Yes
No
No
Interface
εr 1.4–100
-40° to +400° F max 1015 psig
(-40° to +200° C) (70 bar)
Yes
Yes
No
7xR
7xM
7xD
7xL
7xS
7xT
7xN
Liquids – Rod
Liquids – Cable
(level/interface)
Solids – Cable
Twin Rod/Cable GWR Probes: Maximum Viscosity 1500 cP
εr 1.9–100
-40° to +400° F max 1000 psig
(-40° to +200° C) (70 bar)
Yes
No
εr 1.9–100
-40° to +400° F max 1000 psig
(-40° to +200° C) (70 bar)
Yes
No
εr 1.9–100
Ambient
Atmospheric
Yes
No
Yes
7xB
No
7x7
n/a
7x5
Single Rod/Cable GWR Probes: Maximum Viscosity 10,000 cP
Liquids – Rod 
εr 1.9–100
-40° to +300° F max 1000 psig
(-40° to +150° C) (70 bar)
Yes
No
Liquids – Cable 
εr 1.9–100
-40° to +300° F max 1000 psig
(-40° to +150° C) (70 bar)
Yes
No
Solids – Cable
εr 4–100
Ambient
Atmospheric
Yes
No
High Temp./
High Pressure 
εr 1.9–100
-40° to +600° F max 3002 psig
(-40° to +315° C) (207 bar)
Yes
No
ΠEach Eclipse probe can be used for vacuum service (negative pressure) but only the Borosilicate
GWR probes (7xD/7xL) are suited for full vacuum conditions (Helium leak < 10-8 cc/s @ 1 bar abs.)
 Eclipse is ideally suited to be used on foaming applications but in specific conditions where dense
foam can enter in the stilling well, coaxial GWR probes are not recommended.
Ž Depends on the spacer material. See model selection 7xD/7xL GWR probe.
ε  For media with r 1.9 to 10, GWR probe must be mounted between 3" and 6" (75 and 150 mm)
away from the metal tank wall or in a metal cage/stillwell.
Yes
7xF
Yes
7x1
n/a
7x2
Yes
7xJ
5