705-5100-111 Datasheet, PDF (10/28 Pages) Magnetrol International, Inc. – Eclipse® Enhanced Model 705 Guided Wave Radar Level Transmitter | |||
|
◁ |
REPLACEMENT OF DISPLACER TRANSMITTER
Eclipse has proven to be the ideal replacement for exist-
ing torque tube transmitters. In numerous applications
around the world, customers have found Eclipse Guided
Wave Radar superior to torque tube transmitters:
⢠Cost:
A new Eclipse costs only slightly more than rebuilding
an aging torque tube.
⢠Installation:
No ï¬eld calibration is necessary; it can be conï¬gured
in minutes with no level movement. Factory pre-con-
ï¬guration is available.
⢠Performance:
Eclipse is not affected by changes in speciï¬c gravity or
dielectric.
⢠Ease of replacement:
Proprietary ï¬anges are offered so existing chamber/
cages can be used.
In order to match the proper Eclipse transmitter with the
proper external cage, consider the following:
⢠Type of application:
Use the applicable GWR probe, see pages 16 to 27.
⢠Overï¬ll proof:
âOverï¬llâ occurs when the level rises above the maxi-
mum range of operation. Radar based probes may pro-
vide erroneous output in this zone unless an optimal
design is used. Eclipse GWR overï¬ll probes without
top transition zones (e.g., 7xG, 7xR, 7xD, 7xT) are
always safe to use. In cases where the application
demands a different probe type, other selections can
be considered and the recommended installation pre-
cautions should be followed.
⢠Min cage size:
⢠Coaxial type: min 2"
⢠Enlarged Coaxial Type: min 3"
⢠Twin rod type: min 3"
⢠Caged GWR type: 2"
Before
H
Displacer
Length
20 mA / 100 %
4 mA / 0 %
Body connection
E
Measuring range:
min 12" (30 cm)
max 224" (570 cm)
F
P
Probe Insertion Length =
E + measuring range + F
min 1" (25 mm)
After
Recomended probe length for replacing displacer transmitters
The table below helps to deï¬ne the GWR probe length for the most common displacer transmitters.
Refer to the ï¬ange selection guide on the next page.
Manufacturer
Magnetrol®
Type
EZ & PN Modulevel®
Masoneilan®
Series 1200
Fisher® series
2300 & 2500
Eckhardt®
249B, 259B, 249C cages
other cages
Series 134, 144
Tokyo Keiso®
FST-3000
Process connection
ANSI/DIN ï¬ange
Proprietary ï¬ange
ANSI/DIN ï¬ange
Proprietary ï¬ange
ANSI ï¬ange
ANSI/DIN ï¬ange
ANSI/DIN ï¬ange
ANSI/DIN ï¬ange
Displacer length
inches (mm)
⥠14" (356)
⥠14" (356)
⥠16" (406)
⥠14" (356)
⥠14" (356)
⥠14" (356)
H = 11.8" (300)
⥠H = 19.7" (500)
 Round down resulting calculation to the nearest inch.
10
Probe length Â
inches (mm)
Displacer + 7 (178)
Displacer + 8 (203)
Displacer + 8 (203)
Displacer + 10 (254)
consult factory
consult factory
Displacer + 9 (229)
Displacer + 9 (229)
|
▷ |