X3100 Datasheet, PDF (8/40 Pages) Xicor Inc. – 3 or 4 Cell Li-Ion Battery Protection and Monitor IC
X3100/X3101 – Preliminary Information
CONFIGURATION REGISTER
The X3100 and X3101 can be configured for specific
user requirements using the Configuration Register.
Table 1. Configuration Register Functionality
Bit(s) Name
Function
0-5
–
(don’t care)
6
SWCEN
Switch Cell Charge Enable
threshold function ON/OFF
7
CELLN
Set the number of Li-Ion battery
cells used (3 or 4)
8-9
VCE1-VCE0
Select Cell Charge Enable
threshold
10-11 VOC1-VOC0 Select over-current threshold
12-13
VUV1-VUV0
Select over-discharge (under
voltage) threshold
14-15
VOV1-VOV0
Select over-charge voltage
threshold
Table 2. Configuration Register—Upper Byte
15 14 13 12 11 10 9 8
VOV1 VOV0 VUV1 VUV0 VOC1 VOC0 VCE1 VCE0
X3100 Default = 30H; X3101 Default = 00H.
Table 3. Configuration Register—Lower Byte
7
6
543210
CELLN SWCEN x x x x x x
X3100 Default = C0H; X3101 Default = 40H.
Over-charge Voltage Settings
VOV1 and VOV0 control the cell over-charge level. See
section “Over-charge Protection” on page 13.
Table 4. Over-charge Voltage Threshold Selection
Configuration Register
Bits
VOV1
VOV0
0
0
0
1
1
0
1
1
Operation
VOV = 4.20V (Default)
VOV = 4.25V
VOV = 4.30V
VOV = 4.35V
Over-discharge Settings
VUV1 and VUV0 control the cell over-discharge (under
voltage threshold) level. See section “Over-discharge
Protection” on page 15.
Table 5. Over-discharge Threshold Selection.
Configuration
Register Bits
VUV1 VUV0
0
0
0
1
1
0
1
1
Operation
X3100
X3101
VUV=1.95V
VUV=2.25V
(X3101 default)
VUV=2.05V
VUV=2.15V
VUV=2.25V
(X3100 default)
VUV=2.35V
VUV=2.45V
VUV=2.55V
Over-current Settings
VOC1 and VOC0 control the pack over-current level.
See section “Over-Current Protection” on page 18.
Table 6. Over-Current Threshold Voltage Selection.
Configuration Register Bits
VOC1
VOC0
0
0
0
1
1
0
1
1
Operation
VOC=0.075V (Default)
VOC=0.100V
VOC=0.125V
VOC=0.150V
Cell Charge Enable Settings
VCE1, VCE0 and SWCEN control the pack charge
enable function. SWCEN enables or disables a circuit
that prevents charging if the cells are at too low a
voltage. VCE1 and VCE0 select the voltage that is
recognized as too low. See section “Sleep Mode” on
page 15.
Table 7. Cell Charge Enable Function
Configuration
Register Bit
SWCEN
Operation
0
Charge enable function: ON
1
Charge enable function: OFF
REV 1.1.8 12/10/02
www.xicor.com
Characteristics subject to change without notice. 8 of 40