English
Language : 

X76F041 Datasheet, PDF (15/21 Pages) Xicor Inc. – PASS TM SecureFlash
X76F041
RECOMMENDED OPERATING CONDITIONS
Temp
Min.
Max.
Commercial
0°C
+70°C
Extended
–20°C
+85°C
7002 FRM T05
Supply Voltage
X76F041
X76F041 – 3
Limits
4.5V to 5.5V
3V to 3.6V
7002 FRM T06.1
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
ICC1
ICC2(3)
ISB1(1)
ISB2(1)
ILI
ILO
VIL1(2)
VIH1(2)
VIL2(2)
VIH2(2)
VOL
VOH
Parameter
VCC Supply Current (Read)
VCC Supply Current (Write)
VCC Supply Current (Standby)
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Min.
Max.
2
3
100
50
10
10
–0.5 VCC x 0.3
VCC x 0.7 VCC + 0.5
–0.5 VCC x 0.1
VCC x 0.9 VCC + 0.5
0.4
VCC – 0.8
Units
mA
mA
µA
µA
µA
µA
V
V
V
V
V
V
Test Conditions
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 1MHz,
SDA = Open
RST = CS = VSS
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 1MHz,
SDA = Open
RST = CS = VSS
SCL = VSS, CS = VCC – 0.3V
SDA = Open, RST = VCC = 5.5V
SCL = VSS, CS = VCC – 0.3V
SDA = Open, RST = VSS, VCC = 3V
VIN = VSS to VCC
VOUT = VSS to VCC
VCC = 5.5V
VCC = 5.5V
VCC = 3.0V
VCC = 3.0V
IOL = 2mA
IOH = –1mA
7002 FRM T07.1
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
Test
Max.
Units
Conditions
COUT(3)
Output Capacitance (SDA)
10
pF
VI/O = 0V
CIN(3)
Input Capacitance (RST, SCL, CS)
10
pF
VIN = 0V
NOTES: (1) Must perform a stop command after a read command prior to measurement
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
EQUIVALENT A.C. LOAD CIRCUIT
A.C. TEST CONDITIONS
7002 FRM T08
OUTPUT
5V
2.3KΩ
OUTPUT
100pF
3V
1.3KΩ
100pF
Input Pulse Levels
VCC x 0.1 to VCC x 0.9
Input Rise and Fall Times
10ns
Input and Output Timing Level
VCC x 0.5
Output Load
100pF
7002 FRM T09
7002 ILL F21.1
15