ABSOLUTE MAXIMUM RATINGS
Temperature under bias ................... –65°c to +135°C
Storage temperature ........................–65°C to +150°C
Voltage on any pin with respect to VSS..... –1V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds).........300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Extended
Min.
0°C
–20°C
Max.
+70°C
+85°C
Device
X40620
Supply Voltage Limits
2.5V to 3.7V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
ICC2(3)
ISB1(1)
ISB2(1)
ILI
ILO
VIL1(2)
VIH1(2)
VIL2(2)
VIH2(2)
VOL
Parameter
VCC Supply Current (Read)
VCC Supply Current (Write)
VCC Supply Current (Standby)
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Limits
Min.
Max.
1
3
50
1
10
10
–0.5 VCC x 0.3
VCC x 0.7 VCC + 0.5
–0.5 VCC x 0.1
VCC x 0.9 VCC + 0.5
0.4
Units
mA
mA
µA
µA
µA
µA
V
V
V
V
V
Test Conditions
fSCL = 1MHz,
RESET = V2FAIL = VCC w/ pull up resistor
V2MON = VCC
fSCL = 1MHz,
RESET = V2FAIL = VCC w/ pull up resistor
RST = VSS
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 1MHz, fSDA = 400 KHz
VSDA = VSCL = V2MON = VCC
Other = GND or VCC–0.3V
VIN = VSS to VCC
VOUT = VSS to VCC
VCC = 3.0V
VCC = 3.0V
VCC = 3.0V
VCC = 3.0V
IOL = 3mA
CAPACITANCE (TA = +25°C, F = 1MHZ, VCC = 3V)
Symbol
COUT(3)
CIN(3)
Test
Output Capacitance (SDA)
Input Capacitance (WP, SCL, V2MON)
Max.
8
6
Notes: (1) Must perform a stop command after a read command prior to measurement
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
Units
pF
pF
Conditions
VI/O = 0V
VIN = 0V
Characteristics subject to change without notice. 10 of 17