PARAMETER / CONDITION
Operating current:
Active mode, 1 bank, BL = 1, tRC = tRC (min), Iout=0mA,
Active Precharge command cycling without burst operation.
Standby current:
Power-down mode, All banks idle, CKE = LOW.
Standby current:
Nonpower-down mode, All banks idle, CKE = HIGH.
Standby current:
Active mode; CKE = LOW, CS# = HIGH, All banks active,
No accesses in progress.
Standby current:
Active mode, CKE = HIGH, CS# = HIGH, All banks active after
tRCD met,
No accesses in progress.
Operating current:
Burst mode, All banks active, Iout=0mA,
READ/WRITE command cycling,
Auto refresh current:
tRFC=tRFC (MIN), Auto refresh command cycling
Deep Power Down Mode
512Mb Mobile LPSDR
SYM.
-6
-75 UNIT NOTES
MAX. MAX.
IDD1
38 35 mA 2, 3, 4
Idd2P
Low
power
0.6
0.6
mA
5
Normal
power
0.8
0.8
Idd2N
10 10 mA
Idd3P
3
3 mA 3, 4, 6
Idd3N
25 25 mA 3, 4, 6
Idd4
75 70 mA 2, 3, 4
Idd5
75 75 mA 2, 3, 4, 6
Izz
10 10 μA
5,8
Notes:
1. A full initialization sequence is required before proper device operation is ensured.
2. Idd is dependent on output loading and cycle rates. Specified values are obtained with minimum cycle time and the
outputs open.
3. The Idd current will increase or decrease proportionally according to the amount of frequency alteration for the test
condition.
4. Address transitions average one transition every 2 clocks.
5. Measurement is taken 500ms after entering into this operating mode to provide tester measuring unit settling time.
6. Other input signals can transition only one time for every 2 clocks and are otherwise at valid Vih or Vil levels.
7. CKE is HIGH during the REFRESH command period tRFC (MIN) else CKE is LOW. The Idd7 limit is a nominal value
and does not result in a fail value.
8. Typical values at 25°C (not a maximum value).
Publication Release Date: Sep, 22, 2011
-9-
Revision A01-005