English
Language : 

W989D6CB Datasheet, PDF (12/67 Pages) Winbond – 512Mb Mobile LPSDR
PARAMETER
CKE Set-up Time
CKE Hold Time
Command Set-up Time
Command Hold Time
Refresh Time
Mode register Set Cycle
Time
Ref to Ref/Active
Command period
Self Refresh exit to next
valid command delay
W989D6CB / W989D2CB
SYM
tCKS
tCKH
tCMS
tCMH
tREF
tRSC
-6
MIN. MAX.
1.5
1
1.5
1
64
12
512Mb Mobile LPSDR
-75
MIN. MAX. UNIT NOTE
1.5
-
ns
1
-
ns
1.5
-
ns
1
-
ns
64
ms
15
-
ns
8
tRFC 72
72
-
ns
tXSR 115
115
-
ns
6.6.2 AC Test Condition
SYMBOL
VIH(min)
VIL(max)
VREF
VOTR
SLEW
PARAMETER
Input High Voltage Level (AC)
Input Low Voltage Level (AC)
Input Signal Reference Level
Output Signal Reference Level
Input Signal Slew Rate
VALUE
0.8 x VDDQ
0.2 x VDDQ
0.5 x VDDQ
0.5 x VDDQ
1
UNIT
V
V
V
V
V/ns
VDDQ
VIH(min)
VREF
VIL(max)
VSS
tT
tT
SLEW = ( VIH(min)- VIL(max) / tT
Transition times are measured between VIH and VIL.
output
RT=50Ω
VTT=0.9V
Z = 50 Ω
CLOAD = 30pF
AC TEST LOAD
VOTR
- 12 -
Publication Release Date: Sep, 22, 2011
Revision A01-005