8.6 Recommended Operating Conditions
8.6.1 At Device Power-up
AC timing illustrated in Figure A is recommended for the supply voltages and the control signals at
device power-up. If the timing in the figure is ignored, the device may not operate correctly.
min
VCC
min
EVIO
tRH
#CE
#RESET
tEVIOS
tVCS
Figure 8-28 AC Timing at Device Power-Up Reference to #RESET
Description
SYMBOL
ALT STD
MIN MAX
Reset Low Time from rising edge of VCC
tVCS
35
Reset Low time from rising edge of EVIO
tVIOS tEVIOS
35
Reset High Time before Read
tRH
200
Table 8-9
AC Characteristics at Device Power Up
UNIT
µs
µs