English
Language : 

W83791D Datasheet, PDF (34/46 Pages) Winbond – W83791D Winbond H/W Monitoring IC
W83791D
High limit
Low limit
Preliminary
Fan Count limit
SMI#
*
*
*
*
SMI#
*Interrupt Reset when Interrupt Status Registers are read
*
*
Figure 12-1. Voltage SMI# Mode
Figure 12-2. Fan SMI# Mode
6.8.5
SMI# interrupt for W83791D temperature sensor 1/2/3
(1) Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset by reading all the Interrupt Status
Register. Once an interrupt event has occurred by exceeding TO, then reset, if the temperature remains above the
THYST, the interrupt will occur again when the next conversion has completed. If an interrupt event has occurred by
exceeding TO but has not been reset, the interrupts will not occur again. The interrupts will continue to occur in this
manner until the temperature goes below THYST. (Figure 12-3.)
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also cause an interrupt
if the previous interrupt has been reset by reading all the interrupt Status Register. Once an interrupt event has
occurred by exceeding TO , then reset, if the temperature remains above the THYST , the interrupt will not occur.
(Figure 12-4.)
(3) One-Time interrupt mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will not cause an interrupt.
Once an interrupt event has occurred by exceeding TO, then going below THYST, an interrupt will not occur again
until the temperature exceeding TO. (Figure 12-5.)
27
Publication Release Date: Aug, 2001
Revision 0.41