English
Language : 

W83791D Datasheet, PDF (22/46 Pages) Winbond – W83791D Winbond H/W Monitoring IC
W83791D
Relative command list:
Slave address
C2h
C2h
C2h
C2h
C2h
C2h
C2h
Command
01h
02h
03h
04h
Slave_Addr | 1
Slave_Addr | 0
05h-1Fh
Description
Prepare to ARP
Reset device (general)
Get UDID (general)
Assign address
Direct Get UDID
Direct Reset
Reserved.
Preliminary
Following is an example of the Block Write-Block Read Process Call. The Block Write-Block Read Process
Call is a two-part message. It begins with a salve address and a write condition. After the command code the host
issues a write count M that describes how many more bytes will be written in the first part of the message. The
second part of the message is a block of read data beginning with a repeated start condition followed by thee salve
address and a Read Bit. The next read byte count N indicates how many more data will be read in the second part of
the message. Note that the combined data payload must not exceed 32bytes. Besides, W83791D also provides
packet error code (PEC) to insure the accuracy during data transmission.
17
11 8
18
18
S Slave Address Wr A Command Code A Byte Count=M A Data Byte 1
1
A…
8
Data Byte 2
1 …8
1
A … Data Byte M A …
17
118
18
11
Sr Slave Address Rd A Byte Count=N A Data Byte 1 A …
8
1 …8
18 1 1
Data Byte 2 A … Data Byte N A PEC A P
15
Publication Release Date: Aug, 2001
Revision 0.41