Preliminary W83782D
6.5.3 The W83782D temperature sensor 2 and 3 Over-Temperature (OVT#) has two modes,
and they are programmed at Bank1 and Bank2 CR[52h] bit1 . These two bits needs to be
programmed the same value.
(1) Comparator Mode :
Temperature exceeding TO causes the OVT# output activated until the temperature is less than
THYST. ( Figure 17)
(2) Interrupt Mode:
Temperature exceeding TO causes the OVT# output activated indefinitely until reset by reading
temperature sensor 2 or sensor 3 registers. Temperature exceeding TO , then OVT# reset, and
then temperature going below THYST will also cause the OVT# activated indefinitely until reset by
reading temperature sensor2 or sensor 3 registers. Once the OVT# is activated by exceeding TO
, then reset, if the temperature remains above THYST , the OVT# will not be activated again.(
Figure 17)
To
THYST
OVT#
(Comparator Mode; default)
OVT#
(Interrupt Mode)
*
*
*Interrupt Reset when Temperature 2/3 is read
*
*
Figure 17. Over-Temperature Response Diagram
- 23 -