English
Language : 

W956D6HB Datasheet, PDF (24/57 Pages) Winbond – Low-power features
W956D6HB
64Mb Async./Burst/Sync./A/D MUX
8.4.3.2 Burst Length (BCR[2:0]) Default = Continuous Burst
Burst lengths define the number of words the device outputs during burst READ and WRITE operations. The device
supports a burst length of 4, 8, 16, or 32 words. The device can also be set in continuous burst mode where data is
output sequentially without regard to address boundaries; the internal address wraps to 000000h if the device is read
past the last address.
8.4.3.3 Burst Wrap (BCR[3]) Default = No Wrap
The burst-wrap option determines if a 4-, 8-, 16-, or 32-word READ or WRITE burst wraps within the burst length, or
steps through sequential addresses. If the wrap option is not enabled, the device accesses data from sequential
addresses without regard to address boundaries; the internal address wraps to 000000h if the device is read past the
last address.
- 24 -
Publication Release Date : May 29,2013