8411190000 Datasheet, PDF (47/58 Pages) Weidmuller – Mini Coupler / Mini Conditioner | |||
|
◁ |
Current Monitoring
⢠For AC/DC
⢠Adjustable switching threshold
⢠Relay output
SMSI DC R
With adjustable switching threshold
up to 250 mA
SMSI AC R
With adjustable switching threshold
up to 250 mA
Ordering data
Type
Cat. No.
SMSI 0.25 DC R 1156660000
Technical data
Measurement circuit voltage
Max. permissible current in measurement circuit
Rated consumption ~ (VA)
Voltage drop at input
Adjustable switching threshold
Hysteresis between turn-on and turn-off point
Activation time tA
Reaction time tR
Recovery
Output voltage
Max. continuous output current
Auxiliary voltage
Rated consumption auxiliary voltage
Max. switching current
Contact
Contact material
10 Vâ¦250 Vdc
350 mA
750 mVA (l = 250 mA)
⤠3 V (I = 250 mA)
40 mAâ¦250 mAâ
2% (250 mA)<lHY<10% (40 mA)
-
⤠12 ms
-
250 V
3A
24 V~ ±10%
250 mW/450 mVA
8A
1 NO1)
AgNi, gold-flashed
Storage temperature
Ambient temperature
â, assembled without spacing on TS
â, assembled with ⥠20 mm spacing on TS
Coordination of insulation to DIN VDE 0160,Draft 11/94
Overvoltage category, input, output
Overvoltage category, input1-input2,
Output1-output 2, input-output
Contamination class
â25 °Câ¦+60 °C
â25 °Câ¦+40 °C
â25 °Câ¦+50 °C
II
III
2
Dimensions and connection data
see page 307
Fig. V
1) NC on request
202
Type
Cat. No.
SMSI 0.25 AC R 1159960000
10 Vâ¦250 Vac
300 mA
1075 mVA (l = 250 mA)
⤠3 V (I = 250 mA)
40 mAâ¦250 mA~
⤠5%
⤠25 ms
⤠15 ms
-
250 V
3A
24 V~ ±10%
250 mW/450 mVA
8A
1 NO1)
AgNi, gold-flashed
â25 °Câ¦+60 °C
â25 °Câ¦+40 °C
â25 °Câ¦+50 °C
II
III
2
Fig. V
|
▷ |