English
Language : 

PI354X-00 Datasheet, PDF (8/39 Pages) –
PI354x-00
PI354x-00 Common Electrical Characteristics (Cont.)
Specifications apply for -40°C < TJ < 125°C, VIN = 48V, EN = High, VVDR = 5.1V +/- 2%, L1 = 340nH [1] unless other conditions are noted.
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
High Threshold
Low Threshold
Threshold Hysteresis
Enable Pull-Up Voltage
Source Current
VEN_HI
VEN_LO
VEN_HYS
VEN_PU
IEN_SO
Enable
0.9
1
1.1
V
0.7
0.8
0.9
V
100
200
300
mV
2
V
50
µA
Voltage Setpoint
External Loading
VVDR
IVDR
VDR
VIN_DC > 10V
See Application Description for details
4.8
5.1
5.4
V
0
2
mA
Input UVLO Start Threshold
Input UVLO Stop Hysteresis
Input UVLO Response Time
Input OVLO Stop Threshold
Input OVLO Start Hysteresis
Input OVLO Response Time
Output Overvoltage Protection
VUVLO_START
VUVLO_HYS
Protection
VOVLO
VOVLO_HYS
tf
VOVP
Above set VOUT
33.8
34.8
35.8
V
0.9
V
1.25
us
70
V
1.3
V
1.25
µs
20
%
Synchronization Frequency Range
SYNCI Threshold
∆fSYNCI
VSYNCI
Sync In (SYNCI)
Relative to set switching frequency [3]
50
110
%
VVDR / 2
V
Sync Out (SYNCO)
SYNCO High
VSYNCO_HI Source 1mA
VVDR –0.5
V
SYNCO Low
SYNCO Rise Time
VSYNCO_LO
tSYNCO_RT
Sink 1mA
20pF load
0.5
V
10
ns
SYNCO Fall Time
tSYNCO_FT 20pF load
10
ns
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI354x evaluation board with 2.5 x 4”
dimensions and 4 layer, 2 oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control. Output voltage is
determined by an external feedback divider ratio.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when VOUT is not set to nominal.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
Cool-Power® ZVS Switching Regulators
Page 8 of 39