English
Language : 

PI354X-00 Datasheet, PDF (7/39 Pages) –
PI354x-00
PI354x-00 Common Electrical Characteristics
Specifications apply for -40°C < TJ < 125°C, VIN = 48V, EN = High, VVDR = 5.1V +/- 2%, L1 = 340nH [1] unless other conditions are noted.
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Open Loop Gain
Small Signal Gain-Bandwidth
Offset
Common Mode Input Range
Differential Mode Input Range
Input Bias Current
Maximum VOUT
Minimum VOUT
Capacitive Load Range for Stability
Slew Rate Rising
Slew Rate Falling
Sink/Source Current
Differential Amp
IDIFF = ­-1mA
96
120
140
dB
5
7
12
MHz
­-1
0.5
1
mV
-0.1
2.5
V
2
V
-1
1
µA
VVDR - 0.2
V
20
mV
0
50
pF
11
V/µs
11
V/µs
-1
1
mA
LGH Reference
Input Offset
Gain-Bandwidth Product
Internal Feedback Capacitance
Gain
Intermediate Reference
Transconductance
Output Current Capability
VLGH-REF
Current Source Function (LGH)
Sink current only
95
100
107
mV
0.5
mV
3
MHz
20
pF
10
V/V
1
V
1
mS
1
mA
PWRGD
PWRGD Rising Threshold
VPG_HI%
[2]
79
85
91 % VOUT_DC
PWRGD Falling Threshold
VPG_LO%
[2]
77
83
89 % VOUT_DC
PWRGD Output Low
VPG_SAT
Sink = 4mA [2]
0.4
V
PWRGD Sink Current
IPG_SAT
[2]
4
mA
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI354x evaluation board with 2.5 x 4”
dimensions and 4 layer, 2 oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control. Output voltage is
determined by an external feedback divider ratio.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when VOUT is not set to nominal.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
Cool-Power® ZVS Switching Regulators
Page 7 of 39
Rev 1.6
03/2017
vicorpower.com
800 927.9474