PI3543-00 (3.3VOUT) Electrical Characteristics
Specifications apply for -40°C < TJ < 125°C, VIN = 48V, EN = High, VVDR = 5.1V +/- 2%, L1 = 420nH [1] unless other conditions are noted.
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Input Voltage
Input Voltage, Transient
Input Current
Input Current At Output Short
(Fault Condition Duty Cycle)
Input Quiescent Current
Input Voltage Slew Rate
VIN_DC
VIN_TRANS
IIN_DC
IIN_Short
IQ_VIN
VIN_SR
Input Specifications
< 1% duty cycle,entire transient duration < 10ms
VIN = 48V, TC = 25°C, IOUT = 10A
Short at terminals
Disabled
Enabled (no load)
36
48
60
V
70
V
0.762
A
3
-
mA
0.75
mA
1.6
1
V/µs
EAIN Voltage Total Regulation
Output Voltage Trim Range
Line Regulation
Load Regulation
Output Voltage Ripple
Output Current
Maximum Array Size
Output Current, Array of 2
Output Current, Array of 3
Current Limit
Output Specifications
VEAIN
VOUT_DC
[2]
[2] [3]
∆VOUT /∆VIN @ 25°C, 36V < VIN < 60V
∆VOUT /∆IOUT
VOUT_AC
IOUT_DC
@ 25°C, 0.5A < IOUT < 10A
IOUT = 10A, COUT = 6 x 100µF, 20MHz BW [4]
[5]
NParallel
IOUT_DC-ARRAY2 Total array capability, see applications section for details
IOUT_DC-ARRAY2 Total array capability, see applications section for details
IOUT_CL
Typ limit based on nominal 420nH inductor
0.985
1.00
1.015
V
2.6
3.3
3.6
V
0.10
%
0.10
%
62
mVp-p
0
10
A
3
Modules
0
17.7
A
0
25.4
A
11.5
A
Timing
Switching Frequency
fS
[6] 48VIN to 3.3VOUT, 6A out, L1 = 420nH ­±1%
-
400
-
kHz
Fault Restart Delay
tFR_DLY
30
ms
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI354x evaluation board with 2.5 x 4”
dimensions and 4 layer, 2 oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control. Output voltage is
determined by an external feedback divider ratio.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when VOUT is not set to nominal.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.