Specifications, continued
GENERAL
Parameter
Min
Typ
Max
Unit
Note
MTBF
MIL-HDBK-217F
3.6
Mhrs
25°C, GB
Telcordia TR-NT-000332
4.2
Mhrs
Telcordia SR-332
TBD
hrs
Demonstrated
TBD
hrs
Isolation specifications
Voltage
1,500
Vdc
Input to Output
Capacitance
5,100
6,000
pF
Input to Output
Resistance
10
MΩ
Input to Output
Agency approvals (pending)
cTÜVus
UL/CSA 60950, EN 60950
CE Mark
Low voltage directive
Mechanical parameters
See mechanical drawing, Figs.16 and 18
P R E L I M I N A RY Weight
Dimensions
Length
Width
Height
0.43 / 12.25
1.26 / 32
0.85 / 21.5
0.24 / 6
oz / g
in / mm
in / mm
in / mm
Auxiliary Pins (Conditions are at nominal line, full load, and 25°C ambient unless otherwise specified)
Parameter
Primary Control (PC)
DC voltage
Module disable voltage
Module enable voltage
Min
Typ
Max
Unit
4.8
5.0
5.2
V
2.4
2.5
V
2.5
2.6
V
Note
Current limit
2.4
2.5
2.9
mA
Source only
Enable delay time
300
450
µs
See Fig.2
Disable delay time
4
10
µs
Temperature Monitor (TM)
27°C setting
2.95
3.00
3.05
V
Operating junction temperature
Temperature coefficient
10
mV/°C
Full range accuracy
-5
5
°C
Operating junction temperature
Current limit
100
µA
Source only
Figure 13— VOUT at full load vs. PC disable
Figure 14— PC signal during fault
45 Vicor Corporation Tel: 800-735-6200 vicorpower.com
V•I Chip Voltage Transformation Module Rev. 1.6