V048K015T80 Datasheet, PDF (5/20 Pages) Vicor Corporation – VI Chip - VTM Voltage Transformation Module | |||
|
◁ |
Specifications, continued
GENERAL
Parameter
Min
Typ
Max
Unit
Note
MTBF
MIL-HDBK-217F
3.6
Mhrs
25°C, GB
Telcordia TR-NT-000332
4.2
Mhrs
Telcordia SR-332
TBD
hrs
Demonstrated
TBD
hrs
Isolation specifications
Voltage
1,500
Vdc
Input to Output
Capacitance
5,100
6,000
pF
Input to Output
Resistance
10
Mâ¦
Input to Output
Agency approvals (pending)
cTÃVus
UL/CSA 60950, EN 60950
CE Mark
Low voltage directive
Mechanical parameters
See mechanical drawing, Figs.16 and 18
P R E L I M I N A RY Weight
Dimensions
Length
Width
Height
0.43 / 12.25
1.26 / 32
0.85 / 21.5
0.24 / 6
oz / g
in / mm
in / mm
in / mm
Auxiliary Pins (Conditions are at nominal line, full load, and 25°C ambient unless otherwise specified)
Parameter
Primary Control (PC)
DC voltage
Module disable voltage
Module enable voltage
Min
Typ
Max
Unit
4.8
5.0
5.2
V
2.4
2.5
V
2.5
2.6
V
Note
Current limit
2.4
2.5
2.9
mA
Source only
Enable delay time
300
450
µs
See Fig.2
Disable delay time
4
10
µs
Temperature Monitor (TM)
27°C setting
2.95
3.00
3.05
V
Operating junction temperature
Temperature coefficient
10
mV/°C
Full range accuracy
-5
5
°C
Operating junction temperature
Current limit
100
µA
Source only
Figure 13â VOUT at full load vs. PC disable
Figure 14â PC signal during fault
45 Vicor Corporation Tel: 800-735-6200 vicorpower.com
Vâ¢I Chip Voltage Transformation Module Rev. 1.6
Page 5 of 20
|
▷ |