V048K015T80 Datasheet, PDF (15/20 Pages) Vicor Corporation – VI Chip - VTM Voltage Transformation Module | |||
|
◁ |
Application Note (continued)
PRELIMINARY
Closed Loop Application
To compensate for the effect of the VTMâs output resistance on
the load voltage as a function of load current, a feedback loop
can be implemented as shown in Fig.30.
VTMs can also be used in a Factorized Power Architecture
system with VID control of the output voltage as a faster, more
efficient alternative to multiphase VRMs as shown in Fig.31.
High efficiency, high density PRMs in Vâ¢I Chip packages are in
development.
Please consult with Vicor application engineering for specific
application information.
Email:apps@vicr.com; phone: 1-800-927-9474
Off-line DC-DC converters, telecom input DC-DC converters
and switching regulators may be adapted, through a suitable
interface, to provide the PRM function.
FPA Application Example
Unregulated
Input Bus
PRM
Factorized
Bus
Vf
VTM
Vf ⢠K
Load
Figure 30âBasic Factorized Power Architecture with Pre-Regulation Module (PRM) and VTM
FPA Application Example
DC
Distribution
Bus
PRM
Vf = 32-58 Vdc
VTM
32:1
1.0-1.8
Vdc
µP
POL IC
VID Control
Figure 31âPRM and VTM, Closed loop with VID Controller
Analog
Control
45 Vicor Corporation Tel: 800-735-6200 vicorpower.com
Vâ¢I Chip Voltage Transformation Module Rev. 1.6
Page 15 of 20
|
▷ |