English
Language : 

SN74CBTU4411_16 Datasheet, PDF (8/21 Pages) Texas Instruments – Multiplexer/Demultiplexer
SN74CBTU4411
SCDS192A – APRIL 2005 – REVISED FEBRUARY 2016
www.ti.com
6.6 Switching Characteristics
TA = 0°C to 85°C (unless otherwise noted) (see Figure 2 and Figure 3)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
D or H port
400
fmax
S port(1)
84
tpd
ten(tPZL, tPZH) (2)
tdis(tPLZ, tPHZ)(2)
tosk
tesk
tstart (3)
From D or H (input) to D or H (output)
From S (input) to D (output)
From S (input) to D (output)
297
750
2100
750
2100
85
40
20
(1) EN = GND, TC = GND
(2) VBIAS = open
(3) tstart is the time required for the charge-pump circuit output voltage to reach a steady state value after VDD is applied.
UNIT
MHz
ps
ps
ps
ps
ps
µs
6.7 Typical Characteristic
0°C
25°C
85°C
17
15
13
11
9
7
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
Control Input Voltage (V)
VIH = 1.7 V
VIL = 0 V
H0 to 0D0 at –10 mA
Figure 1. ON-State Resistance Across Temperature
8
Submit Documentation Feedback
Copyright © 2005–2016, Texas Instruments Incorporated
Product Folder Links: SN74CBTU4411