English
Language : 

BQ27532-G1 Datasheet, PDF (7/35 Pages) Texas Instruments – Battery Management Unit Impedance Track Fuel Gauge
www.ti.com
bq27532-G1
SLUSBU6B – SEPTEMBER 2014 – REVISED JANUARY 2016
6.13 I2C-compatible Interface Communication Timing Requirements
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
MIN
TYP
MAX
UNIT
tr
tf
tw(H)
tw(L)
tsu(STA)
td(STA)
tsu(DAT)
th(DAT)
tsu(STOP)
t(BUF)
fSCL
SCL or SDA rise time
SCL or SDA fall time
SCL pulse duration (high)
SCL pulse duration (low)
Setup for repeated start
Start to first falling edge of SCL
Data setup time
Data hold time
Setup time for stop
Bus free time between stop and start
Clock frequency (1)
300
ns
300
ns
600
ns
1.3
μs
600
ns
600
ns
100
ns
0
ns
600
ns
66
μs
400 kHz
(1) If the clock frequency (fSCL) is > 100 kHz, use 1-byte write commands for proper operation. All other transactions types are supported at
400 kHz (see I2C Interface and I2C Command Waiting Time).
Figure 1. I2C-Compatible Interface Timing Diagrams
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: bq27532-G1
Submit Documentation Feedback
7