The following command sequences are not supported:
Attempt to write a read-only address (NACK after data sent by master):
Figure 9. Invalid Write
Attempt to read an address above 0x6B (NACK command):
Figure 10. Invalid Read
7.5.4.2 I2C Time Out
The I2C engine releases both SDA and SCL if the I2C bus is held low for 2 seconds. If the fuel gauge is holding
the lines, releasing them frees them for the master to drive the lines. If an external condition is holding either of
the lines low, the I2C engine enters the low-power SLEEP mode.
7.5.4.3 I2C Command Waiting Time
To ensure proper operation at 400 kHz, a t(BUF) ≥ 66 μs bus-free waiting time must be inserted between all
packets addressed to the fuel gauge. In addition, if the SCL clock frequency (fSCL) is > 100 kHz, use individual 1-
byte write commands for proper data flow control. The following diagram shows the standard waiting time
required between issuing the control subcommand to reading the status result. For read-write standard
command, a minimum of 2 seconds is required to get the result updated. For read-only standard commands,
there is no waiting time required, but the host must not issue any standard command more than two times per
second. Otherwise, the gauge could result in a reset issue due to the expiration of the watchdog timer.
S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] A P 66ms
S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] A P 66ms
S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] 1 A DATA [7:0] A DATA [7:0]
Waiting time inserted between two 1-byte write packets for a subcommand and reading results
(required for 100 kHz < fSCL £ 400 kHz)
NP
66ms
S ADDR [6:0] 0 A CMD [7:0] A DATA [7:0] A DATA [7:0] A P 66ms
S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] 1 A DATA [7:0] A DATA [7:0] N P
Waiting time inserted between incremental 2-byte write packet for a subcommand and reading results
(acceptable for fSCL £ 100 kHz)
66ms
S ADDR [6:0] 0 A CMD [7:0] A Sr ADDR [6:0] 1 A DATA [7:0] A DATA [7:0] A
DATA [7:0] A DATA [7:0] N P 66ms
Waiting time inserted after incremental read
Figure 11. I2C Command Waiting Time
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: bq27532-G1
Submit Documentation Feedback
19