English
Language : 

CC2500RGPR Datasheet, PDF (63/99 Pages) Texas Instruments – Low-Cost Low-Power 2.4 GHz RF Transceiver
CC2500
Bit Field Name
7:5 PQT[2:0]
4 Reserved
3 CRC_AUTOFLUSH
2 APPEND_STATUS
1:0 ADR_CHK[1:0]
0x07: PKTCTRL1 – Packet Automation Control
Reset
R/W Description
0 (000)
0
0
1
0 (00)
R/W Preamble quality estimator threshold. The preamble quality
estimator increases an internal counter by one each time a bit is
received that is different from the previous bit, and decreases the
counter by 8 each time a bit is received that is the same as the
last bit.
A threshold of 4∙PQT for this counter is used to gate sync word
detection. When PQT=0 a sync word is always accepted.
R0
R/W Enable automatic flush of RX FIFO when CRC is not OK. This
requires that only one packet is in the RX FIFO and that packet
length is limited to the RX FIFO size.
PKTCTRL0.CC2400_EN must be 0 (default) for the CRC
autoflush function to work correctly.
R/W When enabled, two status bytes will be appended to the payload
of the packet. The status bytes contain RSSI and LQI values, as
well as the CRC OK flag.
R/W Controls address check configuration of received packages.
Setting Address check configuration
0 (00) No address check
1 (01) Address check, no broadcast
2 (10) Address check and 0 (0x00) broadcast
3 (11) Address check and 0 (0x00) and 255 (0xFF)
broadcast
SWRS040C