English
Language : 

DRV5013_16 Datasheet, PDF (6/28 Pages) Texas Instruments – Digital-Latch Hall Effect Sensor
DRV5013
SLIS150E – MARCH 2014 – REVISED FEBRUARY 2016
6.5 Electrical Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
POWER SUPPLIES (VCC)
VCC
VCC operating voltage
ICC
Operating supply current
ton
Power-on time
OPEN DRAIN OUTPUT (OUT)
VCC = 2.5 to 38 V, TA = 25°C
VCC = 2.5 to 38 V, TA = 125°C
rDS(on)
FET on-resistance
Ilkg(off)
Off-state leakage current
PROTECTION CIRCUITS
VCC = 3.3 V, IO = 10 mA, TA = 25°C
VCC = 3.3 V, IO = 10 mA, TA = 125°C
Output Hi-Z
VCCR
IOCP
Reverse supply voltage
Overcurrent protection level
OUT shorted VCC
6.6 Switching Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
OPEN DRAIN OUTPUT (OUT)
td
Output delay time
B = BRP – 10 mT to BOP + 10 mT in 1 µs
tr
Output rise time (10% to 90%)
R1 = 1 kΩ, CO = 50 pF, VCC = 3.3 V
tf
Output fall time (90% to 10%)
R1 = 1 kΩ, CO = 50 pF, VCC = 3.3 V
www.ti.com
MIN
TYP
MAX UNIT
2.5
38
V
2.7
mA
3
3.5
35
50
µs
22
Ω
36
50
1
µA
–22
V
15
30
45 mA
MIN TYP MAX UNIT
13
25
µs
200
ns
31
ns
6.7 Magnetic Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
ƒBW
Bandwidth (2)
DRV5013FA: 1.3 / –1.3 mT
TEST CONDITIONS
BOP
Operate point; see Figure 12
BRP
Release point; see Figure 12
Bhys
Hysteresis; Bhys = (BOP – BRP)
BO
Magnetic offset; BO = (BOP + BRP) / 2
DRV5013AD: 2.7 / –2.7 mT
TA = –40°C to 125°C
BOP
Operate point; see Figure 12
BRP
Release point; see Figure 12
Bhys
Hysteresis; Bhys = (BOP – BRP)
BO
Magnetic offset; BO = (BOP + BRP) / 2
DRV5013AG: 6 / –6 mT
TA = –40°C to 125°C
BOP
Operate point; see Figure 12
BRP
Release point; see Figure 12
Bhys
Hysteresis; Bhys = (BOP – BRP)
TA = –40°C to 125°C
BO
Magnetic offset; BO = (BOP + BRP) / 2
MIN
TYP
20
30
–0.5
1.3
–2.9
–1.3
1.2
2.5
–1.5
0
1
2.7
–5
–2.7
5.4
–1.5
0
3
6
–9
–6
12
–1.5
0
(1) 1 mT = 10 Gauss
(2) Bandwidth describes the fastest changing magnetic field that can be detected and translated to the output.
MAX
UNIT (1)
kHz
2.9 mT
0.5 mT
mT
1.5 mT
5 mT
–1 mT
mT
1.5 mT
9 mT
–3 mT
mT
1.5 mT
6
Submit Documentation Feedback
Product Folder Links: DRV5013
Copyright © 2014–2016, Texas Instruments Incorporated