English
Language : 

DRV5013_16 Datasheet, PDF (15/28 Pages) Texas Instruments – Digital-Latch Hall Effect Sensor
www.ti.com
DRV5013
SLIS150E – MARCH 2014 – REVISED FEBRUARY 2016
Feature Description (continued)
7.3.5 Protection Circuits
The DRV5013 device is fully protected against overcurrent and reverse-supply conditions.
7.3.6 Overcurrent Protection (OCP)
An analog current-limit circuit limits the current through the FET. The driver current is clamped to IOCP. During
this clamping, the rDS(on) of the output FET is increased from the nominal value.
7.3.7 Load Dump Protection
The DRV5013 device operates at DC VCC conditions up to 38 V nominally, and can additionally withstand VCC =
40 V. No current-limiting series resistor is required for this protection.
7.3.8 Reverse Supply Protection
The DRV5013 device is protected in the event that the VCC pin and the GND pin are reversed (up to –22 V).
NOTE
In a reverse supply condition, the OUT pin reverse-current must not exceed the ratings
specified in the Absolute Maximum Ratings.
FAULT
FET overload (OCP)
Load dump
Reverse supply
CONDITION
ISINK ≥ IOCP
38 V < VCC < 40 V
–22 V < VCC < 0 V
Table 1.
DEVICE
Operating
Operating
Disabled
DESCRIPTION
Output current is clamped to IOCP
Device will operate for a transient duration
Device will survive this condition
7.4 Device Functional Modes
The DRV5013 device is active only when VCC is between 2.5 and 38 V.
When a reverse supply condition exists, the device is inactive.
RECOVERY
IO < IOCP
VCC ≤ 38 V
VCC ≥ 2.5 V
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: DRV5013
Submit Documentation Feedback
15