8.7.46 Address: 0x30
Figure 87. 0x30
7
6
5
4
3
2
1
0
CURRENT_K[7:0]
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 49. Address: 0x30
BIT FIELD
7-0 CURRENT_K[7:0]
TYPE
R
DEFAULT DESCRIPTION
0
Stores a coefficient to be used in calculating the true impedance of the actuator from the
diagnostic run. This coeficient will be used in conjunction with DIAG_Z_RESULT parameter.