English
Language : 

MSP430F530X_12 Datasheet, PDF (44/100 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F530x, MSP430F5310
SLAS677C – SEPTEMBER 2010 – REVISED SEPTEMBER 2012
Schmitt-Trigger Inputs – General Purpose I/O(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VIT+ Positive-going input threshold voltage
TEST CONDITIONS
VCC
1.8 V
3V
MIN TYP
0.80
1.50
VIT– Negative-going input threshold voltage
1.8 V
0.45
3V
0.75
Vhys Input voltage hysteresis (VIT+ – VIT–)
1.8 V
0.3
3V
0.4
RPull
CI
Pullup/pulldown resistor
Input capacitance
For pullup: VIN = VSS
For pulldown: VIN = VCC
VIN = VSS or VCC
20
35
5
(1) Same parametrics apply to clock input pin when crystal bypass mode is used on XT1 (XIN) or XT2 (XT2IN).
www.ti.com
MAX
1.40
2.10
1.00
1.65
0.85
1.0
UNIT
V
V
V
50 kΩ
pF
Inputs – Ports P1 and P2(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
t(int)
External interrupt timing (2)
TEST CONDITIONS
VCC
MIN
Port P1, P2: P1.x to P2.x, External trigger pulse width to
set interrupt flag
2.2 V, 3 V
20
MAX UNIT
ns
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse width t(int) is met. It may be set by trigger signals shorter
than t(int).
Leakage Current – General Purpose I/O
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
Ilkg(Px.y)
PARAMETER
High-impedance leakage current
TEST CONDITIONS
(1) (2)
VCC
1.8 V, 3 V
MIN MAX UNIT
±50 nA
(1) The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup/pulldown resistor is
disabled.
Outputs – General Purpose I/O (Full Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VOH High-level output voltage
OL
Low-level output voltage
TEST CONDITIONS
I(OHmax) = –3 mA (1)
I(OHmax) = –10 mA (2)
I(OHmax) = –5 mA (1)
I(OHmax) = –15 mA (2)
I(OLmax) = 3 mA (1)
I(OLmax) = 10 mA (2)
I(OLmax) = 5 mA (1)
I(OLmax) = 15 mA (2)
VCC
1.8 V
3V
1.8 V
3V
MIN
VCC – 0.25
VCC – 0.60
VCC – 0.25
VCC – 0.60
VSS
VSS
VSS
VSS
MAX
VCC
VCC
VCC
VCC
VSS + 0.25
VSS + 0.60
VSS + 0.25
VSS + 0.60
UNIT
V
V
(1) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±100 mA to hold the maximum voltage
drop specified.
44
Submit Documentation Feedback
Copyright © 2010–2012, Texas Instruments Incorporated