English
Language : 

LMH0395 Datasheet, PDF (4/21 Pages) Texas Instruments – 3G HD/SD SDI Dual Output Low Power Extended Reach Adaptive Cable Equalizer
Pin Descriptions – SPI Mode / SPI_EN = VCC
Pin
Name
I/O, Type Description
1
VEE
2
VEE
3
SDI
Ground
Ground
I, SDI
Negative power supply (ground).
Negative power supply (ground).
Serial data true input.
4
SDI
I, SDI
Serial data complement input.
5
VEE
6
SPI_EN
Ground
I, LVCMOS
Negative power supply (ground).
SPI register access enable. This pin has an internal pulldown.
H = SPI register access mode.
L = Pin mode.
7
SDO1_DISABLE I, LVCMOS Output driver 1 (SDO1, SDO1) disable. This pin has an internal pullup.
H (or no connection) = Output driver 1 is in a high impedance state.
L = Output driver 1 is enabled.
8
AEC+
I/O, Analog AEC loop filter external capacitor (1µF) positive connection (capacitor is optional).
9
AEC-
I/O, Analog AEC loop filter external capacitor (1µF) negative connection (capacitor is optional).
10 CD
O, LVCMOS
Carrier detect.
H = No input signal detected.
L = Input signal detected.
11
MUTEREF
I, Analog
Mute reference input. Sets the threshold for CD and (with CD tied to MUTE)
determines the maximum cable to be equalized before muting. MUTEREF may be
either unconnected or connected to ground for normal CD operation.
12
VEE
13 SS (SPI)
Ground
I, LVCMOS
Negative power supply (ground).
SPI slave select. This pin has an internal pullup.
14 SDO0
O, LVDS
Serial data output 0 complement.
15 SDO0
O, LVDS
Serial data output 0 true.
16
VEE
17 SDO1
Ground
O, LVDS
Negative power supply (ground).
Serial data output 1 complement.
18 SDO1
O, LVDS
Serial data output 1 true.
19 MISO (SPI)
O, LVCMOS SPI Master Input / Slave Output. LMH0395 control data transmit.
20
VCC
21 SCK (SPI)
Power
I, LVCMOS
Positive power supply (+2.5V).
SPI serial clock input.
22 MOSI (SPI)
I, LVCMOS
SPI Master Output / Slave Input. LMH0395 control data receive. This pin has an
internal pulldown.
23
VEE
24
VCC
DAP VEE
Ground
Power
Ground
Negative power supply (ground).
Positive power supply (+2.5V).
Connect exposed DAP to negative power supply (ground).
www.ti.com
4