5 Pin Configuration and Functions
KEEP
1
PEAK
2
OSC
3
VIN
4
PW Package
8-Pin TSSOP
Top View
8
7
6
5
DRV110
SLVSBA8B – MARCH 2012 – REVISED JULY 2015
EN
OUT
SENSE
GND
NC
KEEP
PEAK
HOLD
OSC
NC
VIN
PW Package
14-Pin TSSOP
Top View
1
14
2
13
3
12
4
11
5
10
6
9
7
8
NC
EN
STATUS
OUT
NC
SENSE
GND
NAME
EN
GND
HOLD
KEEP
NC
OSC
OUT
PEAK
SENSE
STATUS
VIN
PIN
8-PIN PW(1)
8
5
—
1
—
3
7
2
6
—
4
14-PIN PW
13
8
4
2
1, 6, 10, 14
5
11
3
9
12
7
Pin Functions
I/O
DESCRIPTION
I
Enable
—
Ground
I
Hold current set
I
Keep time set
—
No connect
I
PWM frequency set
O
Solenoid switch gate drive
I
Peak current set
I
Solenoid current sense
O
Open drain fault indicator
I
6-V to 18-V supply
(1) In the 8-pin package, the HOLD pin is not bonded out. For this package, the HOLD mode is configured to default (internal) settings.
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DRV110
Submit Documentation Feedback
3