English
Language : 

DRV110_15 Datasheet, PDF (12/24 Pages) Texas Instruments – Power-Saving Solenoid Controller
DRV110
SLVSBA8B – MARCH 2012 – REVISED JULY 2015
www.ti.com
Table 1. Sample Application Values
VARIABLE
Peak current
Hold current
Keep time
VALUE
150 mA
50 mA
100 ms
For IPEAK, the VREF range is 300 mV to 900 mV, so the IPEAK range is defined by 300 mV / RSENSE to 900 mV /
RSENSE. For IHOLD with the 8-pin package, IHOLD is set by 50 mV / RSENSE. For IHOLD with the 14-pin package, the
VREF range is 50 mV to 150 mV, so the IHOLD range is defined by 50 mV / RSENSE to 150 mV / RSENSE. Based on
these ranges, a suitable RSENSE must be chosen. For the sample values, RSENSE of 1 Ω works for both the 8-pin
and 14-pin package. With RSENSE chosen, RPEAK and RHOLD (if applicable) can be determined using Equation 2
and Equation 3. For the sample values, RPEAK is set to 400 kΩ and RHOLD can be shorted to GND. TI
recommends that a 0-Ω resistor is used for prototyping in case changes to this value are desired.
Next, CKEEP can be set based on Equation 1, 1 µF for the sample values. ROSC can initially be shorted to GND,
but again a 0-Ω resistor is recommended for prototyping. Additionally, a filter on the SENSE line may be added if
it will be in a high noise environment and is recommended for prototyping. Typical values for this are 1 kΩ and
100 pF.
Finally, a FET and current recirculation diode must be chosen based on the current values defined in Table 1.
The current recirculation diode should be a fast recovery diode.
8.2.3 Application Curves
ROSC = 0 Ω
RSENSE = 1 Ω
Rind = 50 Ω
RPEAK = 303 kΩ
CKEEP = 1 μF
Measured on the EVM
Figure 6. ISOLENOID, EN, and VIN vs Time
RHOLD = 0 Ω
Lind = 1 H
12
Submit Documentation Feedback
Product Folder Links: DRV110
Copyright © 2012–2015, Texas Instruments Incorporated