SWAS035A – SEPTEMBER 2016 – REVISED FEBRUARY 2017
4.6 Current Consumption Summary (CC3200SF)
TA = 25°C, VBAT = 3.6 V
PARAMETER
TEST CONDITIONS(1) (2)
MIN TYP MAX UNIT
TX power level = maximum
286
1 DSSS
TX power level = maximum – 4
202
TX
NWP ACTIVE
MCU ACTIVE
6 OFDM
54 OFDM
TX power level = maximum
TX power level = maximum – 4
TX power level = maximum
TX power level = maximum – 4
255
192
232
mA
174
RX
NWP idle connected(3)
1 DSSS
54 OFDM
74
74
25.2
TX power level = maximum
282
1 DSSS
TX power level = maximum – 4
198
TX
NWP ACTIVE
MCU SLEEP
6 OFDM
54 OFDM
TX power level = maximum
TX power level = maximum – 4
TX power level = maximum
TX power level = maximum – 4
251
188
228
mA
170
RX
NWP idle connected(3)
1 DSSS
54 OFDM
70
70
21.2
TX power level = 0
266
1 DSSS
TX power level = 4
184
TX
NWP active
MCU LPDS
6 OFDM
54 OFDM
TX power level = 0
TX power level = 4
TX power level = 0
TX power level = 4
242
176
mA
217
154
1 DSSS
53
RX
54 OFDM
53
NWP LPDS(4)
NWP idle connected(3)
120 µA @ 64KB
135 µA @ 256KB
135
µA
710
µA
MCU
SHUTDOWN
VBAT present and nReset pin pulled low
1
µA
Peak calibration current(5)
VBAT = 3.3 V
VBAT = 2.1 V
450
670
mA
VBAT = 1.85 V
700
(1) TX power level = 0 implies maximum power (see Figure 4-1, Figure 4-2, and Figure 4-3). TX power level = 4 implies output power
backed off approximately 4 dB.
(2) The CC3220x system is a constant power-source system. The active current numbers scale based on the VBAT voltage supplied.
(3) DTIM = 1
(4) LPDS current does not include the external serial flash. The LPDS number of reported is with retention of 256KB of MCU SRAM. The
CC3220x device can be configured to retain 0KB, 64KB, 128KB, 192KB, or 256KB of SRAM in LPDS. Each 64-KB block of MCU
retained SRAM increases LPDS current by 4 µA.
(5) The complete calibration can take up to 17 mJ of energy from the battery over a period of 24 ms. Calibration is performed sparingly,
typically when coming out of HIBERNATE and only if temperature has changed by more than 20°C. The calibration event can be
controlled by a configuration file in the serial flash..
Copyright © 2016–2017, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: CC3220
Specifications
27