1158ĆĂ×Ă488ĆPIXEL CCD IMAGE SENSOR
ą
SOCS015C − OCTOBER 1989 − REVISED JUNE 1996
PARAMETER MEASUREMENT INFORMATION
VO
Blooming Point
With Antiblooming
Enabled
Blooming Point
With Antiblooming
Disabled
Dependent on
Well Capacity
Vsat (min)
Vuse (max)
Level Dependent
Upon Antiblooming
Gate High Level
Vuse (typ)
DR
Vn
camera white clip voltage
DR (dynamic range) +
Vn
Lux
(light input)
Vn = noise floor voltage
Vsat (min) = minimum saturation voltage
Vuse (max) = maximum usable voltage
Vuse (typ) = typical user voltage (camera white clip)
NOTES: A. Vuse (typ) is defined as the voltage determined to equal the camera white clip. This voltage must be less than Vuse (max).
B. A system trade-off is necessary to determine the system light sensitivity versus the signal/noise ratio. By lowering the Vuse (typ),
the light sensitivity of the camera is increased; however, this sacrifices the signal/noise ratio of the camera.
Figure 16. Typical Vsat, Vuse Relationship