absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range for ADB, CDB, TDB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 15 V
Input voltage range for ABG, IAG, SAG1, SAG2, SRG1, SRG2, SRG3, TRG . . . . . . . . . . . . . −15 V to 15 V
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30°C to 85°C
Storage temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30°C to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the substrate terminal.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage for ADB, CDB, TDB
11
12
13 V
Substrate bias voltage
0
V
High level
2 2.5
3
IAG
Low level
−11
−9
SAG1, SAG2
High level
Low level
2 2.5
3
−11
−9
SRG1, SRG2, SRG3
High level
Low level
2 2.5
3
−11
−9
Input voltage, VI‡
TMG
High level
Low level
2 2.5
−11
3V
−9
ABG
High level
Intermediate level§
4
− 2.85
4.5
5
−2 −1.55
Low level
−7.5 −7 −6.5
TRG
High level
Low level
2 2.5
3
−11
−9
ABG
1
Clock frequency, fclock
IAG
SRG1, SRG2, SRG3, TRG
1.2
MHz
7.2
TMG, SAG1, SAG2
3.6
Capacitive load
OUT1, OUT2, OUT3
8 pF
Operating free-air temperature, TA
− 10
40 °C
‡ The algebraic convention, in which the least-positive (most negative) value is designated minimum, is used in this data sheet for clock voltage
levels.
§ Adjustment is required for optimal performance.