English
Language : 

TLC082-Q1_16 Datasheet, PDF (12/38 Pages) Texas Instruments – Wide-Bandwidth High-Output-Drive Single-Supply Operational Amplifiers
TLC082-Q1, TLC084-Q1
SLOS510D – SEPTEMBER 2006 – REVISED AUGUST 2016
40°
Rnull = 0 W
35°
Rnull = 100 W
30°
25°
20°
Rnull = 50 W
15°
Rnull = 20 W
10° VDD = 5 V
RL = 10 kW
5° TA = 25°C
0°
10
100
CL − Load Capacitance − pF
Figure 19. Phase Margin vs Load Capacitance
4
Rnull = 0 W
3.5
3
Rnull = 100 W
2.5
2
Rnull = 50 W
1.5
1 VDD = 5 V
RL = 10 kW
0.5 TA = 25°C
Rnull = 20 W
0
10
100
CL − Load Capacitance − pF
Figure 21. Gain Margin vs Load Capacitance
10.0
9.9
CL = 11 pF
TA = 25°C
9.8
9.7
RL = 10 kW
9.6
9.5
9.4
RL = 600 W
9.3
9.2
9.1
9.0
4 5 6 7 8 9 10 11 12 13 14 15 16
VDD - Supply Voltage - V
Figure 23. Gain-Bandwidth Product vs Supply Voltage
www.ti.com
45°
40°
Rnull = 0 W
35°
30°
Rnull = 50 W
Rnull = 100 W
25°
20°
Rnull = 20 W
15°
10° VDD = 12 V
RL = 10 kW
5° TA = 25°C
0°
10
100
CL − Load Capacitance − pF
Figure 20. Phase Margin vs Load Capacitance
5
Rnull = 0 W
4.5
4
Rnull = 100 W
3.5
3
2.5
Rnull = 50 W
2
1.5
VDD = 12 V
1
RL = 10 kW
0.5 TA = 25°C
Rnull = 20 W
0
10
100
CL − Load Capacitance − pF
Figure 22. Gain Margin vs Load Capacitance
22
21
RL = 600 W and 10 kW
CL = 50 pF
20 AV = 1
19
Slew Rate −
18
17
16
Slew Rate +
15
14
13
12
4 5 6 7 8 9 10 11 12 13 14 15 16
VDD - Supply Voltage - V
Figure 24. Slew Rate vs Supply Voltage
12
Submit Documentation Feedback
Copyright © 2006–2016, Texas Instruments Incorporated
Product Folder Links: TLC082-Q1 TLC084-Q1