English
Language : 

TLC254 Datasheet, PDF (9/21 Pages) Texas Instruments – LinCMOSE QUAD OPERATIONAL AMPLIFIERS
TLC254, TLC254A, TLC254B, TLC254Y, TLC25L4, TLC25L4A, TLC25L4B
TLC25L4Y, TLC25M4, TLC25M4A, TLC25M4B, TLC25M4Y
LinCMOS™ QUAD OPERATIONAL AMPLIFIERS
SLOS003F – JUNE 1983 – REVISED AUGUST 1994
electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC25L4C
TLC25L4AC
TA†
TLC25L4BC
UNIT
MIN TYP MAX
TLC25L4C
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 1 MΩ
25°C
Full range
1.1
10
12
VIO
Input offset voltage
TLC25L4AC
VO = 1.4 V,
RS = 50 Ω,
TLC25L4BC
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 1 MΩ
VIC = 0,
RL = 1 MΩ
25°C
Full range
25°C
Full range
0.9
5
mV
6.5
0.24
2
3
∝VIO
Average temperature coefficient of input
offset voltage
25°C to
70°C
1.1
µV/°C
IIO
Input offset current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
70°C
0.1
pA
7 300
IIB
Input bias current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
70°C
0.6
pA
40 600
VICR
Common-mode input voltage range
(see Note 5)
– 0.2 – 0.3
25°C
to
to
V
4 4.2
– 0.2
Full range
to
V
3.5
0°C
3 4.1
VOH High-level output voltage
VID = 100 mV,
RL = 1 MΩ
25°C
3.2 4.1
V
70°C
3 4.2
0°C
0
50
VOL Low-level output voltage
VID = – 100 mV,
IOL = 0
25°C
70°C
0
50 mV
0
50
AVD
Large-signal differential voltage
amplification
VO = 0.25 V to 2 V, RL = 1 MΩ
0°C
25°C
70°C
50 680
50 520
50 380
V/mV
0°C
60
95
CMRR Common-mode rejection ratio
VIC = VICRmin
25°C
65
94
dB
70°C
60
95
kSVR
Supply-voltage rejection ratio
(∆VDD/∆VIO)
0°C
60
97
VDD = 5 V to 10 V, VO = 1.4 V
25°C
70
98
dB
70°C
60
97
0°C
48
IDD
Supply current (four amplifiers)
VO = 2.5 V,
No load
VIC = 2.5 V,
25°C
40
70°C
31
† Full range is 0°C to 70°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
84
68 µA
56
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265