English
Language : 

TLC254 Datasheet, PDF (13/21 Pages) Texas Instruments – LinCMOSE QUAD OPERATIONAL AMPLIFIERS
TLC254, TLC254A, TLC254B, TLC254Y, TLC25L4, TLC25L4A, TLC25L4B
TLC25L4Y, TLC25M4, TLC25M4A, TLC25M4B, TLC25M4Y
LinCMOS™ QUAD OPERATIONAL AMPLIFIERS
SLOS003F – JUNE 1983 – REVISED AUGUST 1994
electrical characteristics at specified free-air temperature, VDD = 10 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC25M4C
TLC25M4AC
TA†
TLC25M4BC
UNIT
MIN TYP MAX
VIO
Input offset voltage
TLC25M4C
TLC25M4AC
TLC25M4BC
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
25°C
Full range
25°C
Full range
25°C
Full range
1.1
10
12
0.9
5
mV
6.5
0.26
2
3
αVIO
Average temperature coefficient of input
offset voltage
25°C to
70°C
2.1
µV/°C
IIO
Input offset current (see Note 4)
VO = 5 V,
VIC = 5 V
25°C
70°C
0.1
pA
7 300
IIB
Input bias current (see Note 4)
VO = 5 V,
VIC = 5 V
25°C
70°C
0.7
pA
50 600
VICR
Common-mode input voltage range (see
Note 5)
– 0.2 – 0.3
25°C
to
to
V
9 9.2
– 0.2
Full range
to
V
8.5
0°C
7.8 8.7
VOH High-level output voltage
VID = 100 mV,
RL = 100 kΩ 25°C
8 8.7
V
70°C
7.8 8.7
0°C
0
50
VOL Low-level output voltage
VID = – 100 mV,
IOL = 0
25°C
70°C
0
50 mV
0
50
AVD
Large-signal differential voltage
amplification
VO = 1 V to 6 V,
RL = 100 kΩ
0°C
25°C
70°C
15 320
25 275
15 230
V/mV
0°C
60
94
CMRR Common-mode rejection ratio
VIC = VICRmin
25°C
65
94
dB
70°C
60
94
0°C
60
92
kSVR Supply-voltage rejection ratio (∆VDD/∆VIO) VDD = 5 V to 10 V, VO = 1.4 V
25°C
70
93
dB
70°C
60
94
IDD
Supply current (four amplifiers)
VO = 5 V,
No load
VIC = 5 V,
0°C
25°C
70°C
690 1600
570 1200 µA
440 1120
† Full range is 0°C to 70°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
14
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265