English
Language : 

TLC254 Datasheet, PDF (4/21 Pages) Texas Instruments – LinCMOSE QUAD OPERATIONAL AMPLIFIERS
TLC254, TLC254A, TLC254B, TLC254Y, TLC25L4, TLC25L4A, TLC25L4B
TLC25L4Y, TLC25M4, TLC25M4A, TLC25M4B, TLC25M4Y
LinCMOS™ QUAD OPERATIONAL AMPLIFIERS
SLOS003F – JUNE 1983 – REVISED AUGUST 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
Differential input voltage (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 18 V
Input voltage range (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 18 V
Duration of short-circuit at (or below) 25°C free-air temperature (see Note 3) . . . . . . . . . . . . . . . . . . unlimited
Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to VDD – /GND.
2. Differential voltages are at IN+, with respect to IN –.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure the maximum dissipation
rating is not exceeded.
PACKAGE
D
N
PW
DISSIPATION RATING TABLE
TA ≤ 25°C
POWER RATING
725 mW
1050 mW
700 mW
DERATING FACTOR
ABOVE TA = 25°C
5.8 mW/°C
9.2 mW/°C
5.6 mW/°C
TA = 70°C
POWER RATING
464 mW
736 mW
448 mW
recommended operating conditions
Supply voltage, VDD
VDD = 1.4 V
Common-mode input voltage, VIC
VDD = 5 V
VDD = 10 V
VDD = 16 V
Operating free-air temperature, TA
MIN
1.4
0
– 0.2
– 0.2
– 0.2
0
MAX
16
0.2
4
9
14
70
UNIT
V
V
°C
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265